LK-E Series Electrostatic Precipitator
for Commercial Kitchen Exhaust

Polygee’s engineering-grade in-duct ESP family, supplied in three filtration grades — LK-E2 (≥ 98% design), LK-E1 (≥ 95% design) and LK-E0 (≥ 90% design) — covering 3,000 to 40,000 m³/h at 220V/50Hz. Patented dual-zone plate-type electrostatic field, drawer-style washable collector cells, and standard flanges that let UV-C and activated carbon modules join the same duct run.

90 / 95 / 98%
Design Efficiency · E0 / E1 / E2
40,000
m³/h Largest Model (LK400E0)
33
Models Available
225
Patents Granted
CE
FQC2602501 · RoHS · ISO

Engineering-Grade LK-E Electrostatic Precipitator

The LK-E series is the in-duct ESP Polygee supplies when the purification stage is specified as a duct component on a project drawing rather than as a packaged appliance. Patented dual-zone plate-type electrostatic field, drawer-style stainless steel collector cells, standard flange connections. The brochure lineup runs to 33 models across three tiers — LK-E2 at ≥ 98% design efficiency, LK-E1 at ≥ 95% and LK-E0 at ≥ 90% — covering 3,000 to 40,000 m³/h, all on a 220V/50Hz supply. UV-C photolysis and activated carbon drawer modules share the same cabinet interface, so odor control can be added to the same run.

90 / 95 / 98%Design Efficiency by Tier
3,000–40,000 m³/hAirflow Range
23–34 PaEquipment Resistance
CE • RoHS • ISOLK-E Certifications
Contact Us →
Polygee LK-E2 Series engineering electrostatic precipitator for commercial kitchen exhaust
Modular Combination

Modular ESP + UV + Carbon: Three Stages You Can Combine in One Duct Run

LK-E cabinets, UV-C photolysis modules and activated carbon modules share the same flange interface and drawer layout, so a project can start with the electrostatic stage alone and add odor control later without reworking the duct. Supplied pre-configured as one train, this arrangement is what a tender calls a kitchen ecology unit.

LK-E modular combination diagram — single unit, multi-layer stacking and ESP + UV + CB configurations
🧩 How the Stages Combine
  • Stage 1 — LK-E electrostatic precipitator: 33 models, 3,000–40,000 m³/h, 220V/50Hz, equipment resistance 23–34 Pa depending on tier
  • Stage 2 — UV-C photolysis module: 8 models UV30–UV150, 3,000–15,000 m³/h, 220V/50Hz, maintenance clearance D = 1,000 mm
  • Stage 3 — activated carbon module: 8 models CB30–CB150, 3,000–15,000 m³/h, 150 Pa equipment resistance, 4 / 8 / 12 carbon frames by size
  • Units combine horizontally and stack in one, two or three layers to match the duct cross-section
  • UV lamps and activated carbon media are consumables and are replaced on a service schedule
Product Series

Three LK-E Tiers, One Modular Kitchen ESP Platform

Pick the tier by the emission target the project has to hit and by how much resistance the exhaust fan can absorb. All three tiers run on 220V/50Hz and share the same drawer-style washable cells.

Polygee LK-E1 Series engineering ESP

LK-E1 Series

Balanced Tier
≥ 95%
Design Efficiency
  • Airflow: 3,000 – 24,000 m³/h
  • Equipment resistance: 23 Pa — lowest of the three tiers
  • 11 models: LK30E1 – LK240E1
  • Input power: 220V/50Hz
  • 560 mm deep cabinet — tight plant-room fit
  • Drawer-style washable collector cells
  • Same flange pattern as LK-E0 at matching airflow
View LK-E1 Specifications ↓
Polygee LK-E0 Series engineering ESP

LK-E0 Series

Standard Tier
≥ 90%
Design Efficiency
  • Airflow: 4,000 – 40,000 m³/h
  • Equipment resistance: 31 Pa
  • 11 models: LK40E0 – LK400E0
  • Input power: 220V/50Hz
  • Widest airflow range in the LK-E family
  • 560 mm deep cabinet
  • Drawer-style washable collector cells
View LK-E0 Specifications ↓
Industry Background

Why Commercial Kitchens Need ESP Purification

Cooking Fumes Are a Serious Health & Safety Risk

Kitchen exhaust carries grease particles, PM2.5, VOCs and carcinogenic compounds that contribute to respiratory problems and lung damage among kitchen staff. Grease that passes through a mesh filter settles inside the ductwork, and grease-loaded ductwork is a common cause of commercial kitchen fires.

Regulatory Compliance Is Mandatory

Cities worldwide enforce emission standards for commercial kitchens, and failure to comply brings fines, forced closures and disputes with neighbors. An electrostatic precipitator is an effective way to help meet EPA, EU and local emission requirements — the applicable limit and the test method still depend on your jurisdiction.

  • Removes grease, smoke and oil mist at 90% / 95% / 98% design efficiency by tier
  • Reduces grease buildup in ductwork — lowers fire risk
  • Supports compliance with EPA, EU and local emission requirements
  • Protects kitchen staff from prolonged fume exposure
  • Addresses neighbor complaints about smoke and odor
  • Washable drawer cells — no disposable filter waste stream
Polygee kitchen exhaust purification product family — ESP, UV-C and activated carbon modules
Product Advantages

Engineering-Grade ESP Construction

Since 2004, Polygee has been engineering ESP solutions. 225 patents granted. BSE-listed (920802). 110,000㎡ production base.

Dual-Zone Plate-Type Cells

Ionization and collection are separated into two zones. Stainless steel plates, washable and reusable, pulled out as drawers for cleaning.

SPP High-Voltage Power Supply

Self-developed switched-mode supply with microsecond-level arc suppression and automatic reset after a short circuit.

Low Equipment Resistance

23 Pa on LK-E1, 31 Pa on LK-E0 and 34 Pa on LK-E2 for the electrostatic stage — a small share of a typical fan’s static budget.

Safety Interlock

Opening the maintenance door breaks the high-voltage circuit, so the field is dead before a cell is touched.

Three Filtration Grades

≥ 90%, ≥ 95% and ≥ 98% design efficiency, so the tier can be matched to the emission target instead of over-specified across a whole site.

Stackable Cabinet Platform

Standard flanges, one, two or three layers stacked, horizontal combination — the array is built to the duct cross-section you already have.

Shared Module Interface

UV-C and activated carbon drawer modules use the same interface, so odor control can be added to an existing LK-E run later.

Washable, Not Replaceable

Cells are soaked in alkaline degreaser or run through a commercial dishwasher and returned to service — no recurring media purchase for the ESP stage.

Working Principle

Principle of Electrostatic Purification

Each LK-E tier runs a multi-stage process through the same cabinet. Select a tier below to see how its stages are arranged.

Stage 1

Airflow Distribution

A washable mesh pre-filter catches the coarse droplets and spreads the airflow evenly across the cabinet section.

→
Stage 2

Ionization Zone

The high-voltage ionizing wires put a charge on the grease and smoke particles carried in the airstream.

→
Stage 3

Primary Collection

Charged particles are drawn onto the first bank of grounded plates. Collected grease drains down to the tray.

→
Stage 4

Secondary Collection

The deeper 848 mm LK-E2 cabinet carries a second collection bank — the reason this tier is rated ≥ 98% by design.

→
Stage 5

Optional Odor Control

A UV-C module downstream decomposes VOCs and reduces cooking odors; an activated carbon module can follow it.

Technology Advantage

Why Dual-Zone Plate-Type ESP as Primary Filtration

Prolonged Wash Cycle & Longer Life

Wider electrode spacing and stainless steel construction let the plate-type cell tolerate a higher working voltage, hold a heavier grease load between washes and survive rigorous cleaning cycles — which is what keeps an engineering-grade unit in service for years.

Higher Collection Efficiency

The dual-zone structure gives a large collection surface with uniform electrode spacing, so field intensity stays even across the cabinet section — the basis for the ≥ 90% / ≥ 95% / ≥ 98% tier ratings.

Separated Ionization & Collection

Charging and collecting happen in two distinct zones rather than one, which lets each zone be tuned separately. The SPP high-voltage supply energizes the field and holds it steady as the grease load builds.

Easy Maintenance & Cleaning

Collector cells slide out as drawers. Soak them in alkaline degreaser or run them through a commercial dishwasher, then slide them back — washable and reusable, with no disposable media cost for the electrostatic stage.

Smart Core Technology

Electrostatic Field & Intelligent Power Supply

The two components Polygee develops and builds in-house — the collecting field and the high-voltage supply that drives it.

Polygee LK-E dual-zone plate-type electrostatic collecting field
Collecting Field

Dual-Zone Plate-Type Cell

✅ Two Zones
Ionization and collection are separated, so each zone can be tuned to its own job.
🧰 Drawer Format
Cells pull straight out of the cabinet for cleaning and slide back on the same rails.
💧 Grease Drainage
Captured grease runs off the plates into the collection tray instead of re-entraining.
📏 Tiered Depth
560 mm cabinets on LK-E0 and LK-E1; 848 mm on LK-E2 for the second collection bank.
Smart Power Supply

SPP Intelligent High-Voltage Power

⚡ Arc Suppression
Microsecond-level automatic arc extinction with multiple discharge protections and auto reset after a short circuit.
🌡 Heat Dissipation
Precision-designed integral heat sink structure for continuous duty inside a warm kitchen exhaust plenum.
🛡 Safety Protection
Over-load, over-temperature and open-circuit protection built into the supply.
🔌 Rich Interfaces
Work, clean and fault indicator ports plus a BMS port for building management integration.
Polygee SPP intelligent high-voltage ESP power supply
Product Models

Model Specifications — 33 LK-E Models

Every figure below is taken from the LK-E brochure. Select the tier your project calls for, then match the model to your extract rate and the space you have in the duct run.

📋 LK-E2 — high-capture tier, 11 models. Design efficiency ≥ 98% • equipment resistance 34 Pa • input power 220V/50Hz across the whole tier. Cabinet depth 848 mm. 1 m³/h ≈ 0.589 CFM. ESP certifications & document numbers →
Model Airflow (m³/h) Rated Power (W) Dimensions L×W×H (mm) Flange A×B (mm) Weight (kg)
LK30E2 3,000 112 678×848×833 431×614 95
LK40E2 4,000 154 846×848×833 599×614 112
LK50E2 5,000 182 898×848×833 651×614 120
LK60E2 6,000 224 1188×848×833 941×614 151
LK80E2 8,000 308 1524×848×833 1277×614 189
LK100E2 10,000 364 1628×848×833 1381×614 205
LK120E2 12,000 462 2202×848×833 1955×614 268
LK150E2 15,000 546 2358×848×833 2111×614 292
LK160E2 16,000 616 1524×848×1536 1277×1317 368
LK200E2 20,000 728 1628×848×1536 1381×1317 400
LK240E2 24,000 924 2202×848×1536 1955×1317 524

Equipment resistance: 34 Pa • Input power: 220V/50Hz • Design efficiency: ≥ 98%

Request Custom Configuration →
📋 LK-E1 — balanced tier, 11 models. Design efficiency ≥ 95% • equipment resistance 23 Pa • input power 220V/50Hz across the whole tier. Cabinet depth 560 mm. The brochure table for this tier does not print a rated power figure; the electrical load is confirmed with your quotation. 1 m³/h ≈ 0.589 CFM. CE certified kitchen ESP documents →
Model Airflow (m³/h) Dimensions L×W×H (mm) Flange A×B (mm) Weight (kg)
LK30E1 3,000 678×560×833 431×614 61
LK40E1 4,000 846×560×833 599×614 71
LK50E1 5,000 898×560×833 651×614 76
LK60E1 6,000 1188×560×833 941×614 95
LK80E1 8,000 1524×560×833 1277×614 116
LK100E1 10,000 1628×560×833 1381×614 125
LK120E1 12,000 2202×560×833 1955×614 168
LK150E1 15,000 2358×560×833 2111×614 182
LK160E1 16,000 1524×560×1536 1277×1317 224
LK200E1 20,000 1628×560×1536 1381×1317 242
LK240E1 24,000 2202×560×1536 1955×1317 326

Equipment resistance: 23 Pa • Input power: 220V/50Hz • Design efficiency: ≥ 95%

Request Custom Configuration →
📋 LK-E0 — standard tier, 11 models and the widest airflow range in the family. Design efficiency ≥ 90% • equipment resistance 31 Pa • input power 220V/50Hz across the whole tier. Cabinet depth 560 mm. The brochure table for this tier does not print a rated power figure; the electrical load is confirmed with your quotation. 1 m³/h ≈ 0.589 CFM. ESP compliance documents →
Model Airflow (m³/h) Dimensions L×W×H (mm) Flange A×B (mm) Weight (kg)
LK40E0 4,000 678×560×833 431×614 61
LK60E0 6,000 846×560×833 599×614 71
LK80E0 8,000 898×560×833 651×614 76
LK100E0 10,000 1188×560×833 941×614 95
LK120E0 12,000 1524×560×833 1277×614 116
LK150E0 15,000 1628×560×833 1381×614 125
LK200E0 20,000 2202×560×833 1955×614 168
LK220E0 22,000 2358×560×833 2111×614 184
LK250E0 25,000 1524×560×1536 1277×1317 224
LK300E0 30,000 1628×560×1536 1381×1317 242
LK400E0 40,000 2202×560×1536 1955×1317 326

Equipment resistance: 31 Pa • Input power: 220V/50Hz • Design efficiency: ≥ 90%

Request Custom Configuration →
Installation Guide

Flexible Installation for Any Kitchen Environment

LK-E units mount wherever the duct route allows — indoors at ceiling level, on the roof, or at ground level outside the building.

Indoor ceiling-mounted LK-E ESP installation

Indoor Ceiling-Mounted

The unit hangs indoors at ceiling level and the exhaust duct carries on to the roof. Keeps the cabinet out of the weather and the maintenance door within easy reach.

Rooftop LK-E ESP installation

Rooftop Installation

Unit and ductwork both sit on the roof, which frees up indoor plant space. Weather protection for the enclosure is specified with the project.

Outdoor ground-level LK-E ESP installation

Outdoor Ground-Level

The unit stands at ground level outside the building and connects back into the exhaust duct — the usual answer when roof access is limited.

📐 Installation Requirements
  • Standard flange connections — compatible with rectangular ductwork
  • Single, double and triple stacking supported, plus horizontal combination across the duct section
  • Power supply: 220V/50Hz across all 33 LK-E models
  • No hood replacement needed — the LK-E cabinet joins the existing duct run
  • Leave clear space in front of the maintenance door for cell removal; the exact clearance is confirmed for your model at quotation
  • UV-C and activated carbon drawer modules need D = 1,000 mm of maintenance clearance
  • Retrofit installation typically takes 4–8 hours during off-peak hours
  • Support horizontal and vertical mounting orientations
Get a Quote

Request a Free Quote

Tell us the extract rate, the emission target and the space you have in the duct run. Our engineering team responds within 24 hours (Mon–Fri) with a tier recommendation, a model number and a quotation.

Request a Quote for the LK-E Series

Fill out the form below. We respond within 24 hours (Mon–Fri) with a detailed proposal and factory-direct pricing.

24h Response (Mon–Fri) NDA Available Factory Direct Free Consultation

1-year warranty on the complete unit • MOQ 1 unit • Lead time 7–15 days • Support Mon–Fri 8:00–17:00 (GMT+8)

📧 Email

scarlett@polygee.com

Scarlett — Business Director

📱 WhatsApp

+86 159 5010 9153

📄 Commercial Terms

Payment: 30% deposit (50% on some orders), balance paid in full before shipment; T/T, L/C and other common bank instruments accepted.

Trade terms: Incoterms arranged to suit the buyer (EXW / FOB / CIF).

Warranty: 1 year on the complete unit — electrostatic collector cells and the SPP high-voltage power supply covered; UV lamps and activated carbon media are consumables and are excluded; labor and travel not included, paid site visits available.

MOQ 1 unit • Standard lead time 7–15 days • OEM quantity and lead time agreed case by case. · Project and volume pricing quoted per project.

Spare parts: common items held in stock; dispatch timing confirmed per order; parts supplied for 1 year after a model is discontinued.

Engineering Support: System design proposals, CAD drawings and full specification sheets — request with your project’s airflow details.

🏭 Manufacturer

Jiangsu Polygee Environmental Technology Co., Ltd.

BSE Listed: 920802 • 225 Patents Granted

110,000㎡ Production Base, Zhangjiagang, China

Kitchen ESP distributor programme →

📜 LK-E Certifications

CE (FQC2602501, covering LK30–480, LK-E and UV) • RoHS (BKC25114877LC) • ISO 9001 (ABZB25Q30072R3M) / ISO 14001 (ABZB25E30043R3M) / ISO 45001 (ABZB25S30027R2M)

The UL 867 Listing (File E522667) covers the 6K, 12K and 18K models at 230V/50Hz and does not extend to the LK-E series. We confirm the exact certificate match for your chosen model at quotation.

FAQ

LK-E Engineering ESP: Frequently Asked Questions

Common questions about the Polygee LK-E engineering electrostatic precipitator series.

What is the LK-E series and how does it differ from the LK in-duct ESP range?

▼
The LK-E series is Polygee’s engineering-grade in-duct electrostatic precipitator, built for project work where the purification stage is specified as a duct component rather than as a packaged appliance. It runs on the same patented dual-zone plate-type electrostatic field as the LK range, with drawer-style washable collector cells and standard flange connections. The brochure lineup covers 33 models in three tiers — LK-E0, LK-E1 and LK-E2 — from 3,000 to 40,000 m³/h, all at 220V/50Hz. The LK-E cabinet is designed to stack and to sit in line with the UV-C and activated carbon drawer modules, so a project can be built up stage by stage.

What is the difference between LK-E0, LK-E1 and LK-E2?

▼
The three tiers differ in collection capacity and in the resistance they add to the duct. LK-E2 is the high-capture tier, rated ≥ 98% design efficiency at 34 Pa equipment resistance, 11 models from LK30E2 to LK240E2 covering 3,000–24,000 m³/h, with rated power from 112 W to 924 W. LK-E1 is the balanced tier, rated ≥ 95% design efficiency at 23 Pa, 11 models from LK30E1 to LK240E1 covering the same 3,000–24,000 m³/h. LK-E0 is the standard tier, rated ≥ 90% design efficiency at 31 Pa, 11 models from LK40E0 to LK400E0 covering 4,000–40,000 m³/h — the widest airflow range in the family. All three share the same dual-zone plate-type cell technology and the same 220V/50Hz supply.

How much airflow can a single LK-E unit handle?

▼
A single LK-E0 unit runs to 40,000 m³/h (LK400E0), which is the largest single unit in the LK-E family. LK-E1 and LK-E2 each run to 24,000 m³/h (LK240E1 and LK240E2). The smallest units start at 3,000 m³/h for LK-E1 and LK-E2 and at 4,000 m³/h for LK-E0. For 1 m³/h read roughly 0.589 CFM. Above the single-unit ceiling, units are combined horizontally or stacked in two or three layers, and our engineering team lays out the arrangement for your duct run.

What is the pressure drop of an LK-E unit?

▼
Equipment resistance is a fixed figure per tier in the brochure: 23 Pa for LK-E1, 31 Pa for LK-E0 and 34 Pa for LK-E2. Those figures are for the electrostatic stage itself. Add the resistance of any UV-C or activated carbon module placed downstream — the carbon module is rated 150 Pa — plus the ductwork and any airflow distribution plate, then size the exhaust fan against the total. Because the collector cells are washed rather than replaced, resistance stays steady over a maintenance cycle instead of climbing the way a loaded mesh filter does.

Can UV-C and activated carbon modules be added to an LK-E system?

▼
Yes. The LK-E cabinet is built as one stage in a modular line. A UV-C photolysis module can be placed downstream to work on cooking odors and VOCs, and an activated carbon module can be placed after that for residual odor adsorption. The UV range covers 8 models from UV30 to UV150, 3,000–15,000 m³/h at 220V/50Hz. The carbon range covers 8 models from CB30 to CB150 over the same airflow band, holding 4, 8 or 12 carbon frames depending on size. Both are drawer modules and both need D = 1,000 mm of maintenance clearance. UV lamps and carbon media are consumables.

What certifications cover the LK-E series?

▼
The LK-E series is covered by CE certificate FQC2602501, which covers the LK30–480 range, the LK-E series and the UV modules. It is also covered by RoHS certificate BKC25114877LC. Polygee holds ISO 9001 (ABZB25Q30072R3M), ISO 14001 (ABZB25E30043R3M) and ISO 45001 (ABZB25S30027R2M). Please note the boundary: the UL 867 Listing under File E522667 covers the 6K, 12K and 18K models at 230V/50Hz and does not extend to the LK-E series. Ask us to confirm the certificate that matches your chosen model at quotation.

How is an LK-E unit installed and maintained?

▼
LK-E units connect to rectangular ductwork through standard flanges, so an existing hood does not need to be replaced. They mount indoors at ceiling level, on the roof, or at ground level outside the building, and they support single, double and triple stacking as well as horizontal combination. A typical retrofit takes 4–8 off-peak hours. The collector cells slide out as drawers and are cleaned by soaking in an alkaline degreaser or running them through a commercial dishwasher — roughly every one to two weeks under heavy wok or BBQ cooking, and every one to two months under lighter loads. Leave clear space in front of the maintenance door for cell removal; the exact clearance is confirmed for your model at quotation.

What warranty and after-sales support come with the LK-E series?

▼
The complete unit carries a 1-year warranty. The electrostatic collector cells and the SPP high-voltage power supply are covered for that period. UV lamps and activated carbon media are consumables and are not covered. Labor and travel are not included — engineer site visits are offered as a paid service. Remote support runs on video call with illustrated manuals, Mon–Fri 8:00–17:00 (GMT+8). Commonly used spare parts are held in stock, dispatch timing is confirmed per order, and parts are supplied for 1 year after a model is discontinued. Polygee is a BSE-listed manufacturer (stock code 920802) with 225 patents granted and a 110,000㎡ production base, exporting to 50 countries.