The Challenge: Why Commercial Kitchens Need Better Exhaust Solutions

In any bustling city, commercial kitchen exhaust is a growing problem. Dense cooking smoke drifts toward residential buildings. Grease accumulates inside ductwork, creating serious fire hazards. Traditional metal mesh filters capture only 40%–60% of grease particles — the rest becomes a ticking time bomb.

As environmental regulations tighten worldwide, a high-efficiency exhaust purification system is no longer optional — it is the lifeline of every commercial kitchen.

Electrostatic precipitation (ESP) technology is the answer. By using high-voltage electrostatic fields to capture grease at the molecular level, ESP systems achieve 90%–99% removal efficiency without disposable filters — far beyond what any passive mesh or baffle filter can deliver.


Our Story: 20 Years Dedicated to One Mission

Founded in 2004 in Zhangjiagang, Jiangsu Province, Polygee has spent two decades focused on a single mission: manufacturing the world’s most reliable commercial kitchen electrostatic precipitators.

  • 2004 — Company founded in Zhangjiagang, dedicated to ESP R&D and manufacturing
  • Corporate Restructuring — Transformed into a joint-stock company with modern governance
  • NEEQ Listing (920802) — Secured capital for technology expansion and global market development
  • 2010s — Achieved CE, RoHS, ISO 9001, ISO 14001, and ISO 45001 certifications
  • 2020 — Recognized as a "Demonstration Smart Workshop"; launched IoT-enabled DESP series
  • 2023 — IPO on Beijing Stock Exchange (BSE: 920802) — China’s first A-share listed fume purification company; UL certified for North America

Today, Polygee holds 179 patents, operates a 100,000+ sqm smart factory with 300+ employees, and exports to 50+ countries across five continents.


Our Core Technology: Plate-Type Electrostatic Field

At the heart of every Polygee ESP is our proprietary dual-zone plate-type electrostatic field — the technology that sets us apart. Unlike honeycomb designs, our plate-type architecture separates ionization and collection into two independent, optimized stages.

LK-K Series 5-stage dual-zone plate-type ESP purification principle LK-D Series 4-stage plate-type ESP working principle LK-A Series ESP filtration principle

Stage 1 — Ionization: High-voltage wires (12–13kV) charge every grease and smoke particle, including sub-micron oil mist invisible to the naked eye.

Stage 2 — Collection: Flat aluminum plates with alternating polarity attract and deposit charged particles. Grease drains to collection trays automatically.

Why Plate-Type Outperforms Honeycomb

  • 90%–99% efficiency — Independent ionization and collection with zero interference
  • Easy cleaning — Flat plates with no dead zones; soak in degreaser or run through a dishwasher
  • 10+ year lifespan — Washable and reusable collector cells with zero consumable costs
  • Lower maintenance — Quarterly cleaning vs. monthly for honeycomb designs

Intelligent Power Supply

Polygee self-developed SMPS intelligent high-voltage power supply
  • Adaptive voltage — Auto-adjusts output based on real-time exhaust load
  • Arc suppression — Automatic fault detection, instant cut-off and self-recovery
  • 30% energy savings compared to traditional line-frequency power supplies

These core technologies are protected by 179 authorized patents (39 invention + 81 utility model + 59 design).


Our Product Lines

We manufacture a complete product range for commercial kitchen exhaust purification — from grease removal to odor elimination.

Polygee LK-K Series ESP 98 percent efficiency Polygee LK-D Series ESP 95 percent efficiency Polygee LK-A Series ESP 90 percent efficiency
SeriesEfficiencyStagesBest ForKey Feature
LK-K≥98%5-stageLuxury hotels, strict emission zonesDual plates + UV module
LK-D≥95%4-stageChain restaurants, hotel kitchensBest value plate-type field
LK-A≥90%4-stageStandard restaurants, bulk ordersMost cost-effective

Complementary Products

Integrated Kitchen ESP Hood UV-C Photolysis Odor Control Module Activated Carbon Adsorption Filter

Explore All Products →


Industry Solutions

Every kitchen is different. We provide tailored ESP configurations for six core commercial scenarios.

Restaurant kitchen ESP solution Hotel central kitchen ESP system Food court ESP exhaust purification
BBQ smoke control ESP solution Cafe bakery ESP filtration Multi-cuisine restaurant ESP
  • Restaurant Kitchen — Chinese wok, Western grill, Japanese teppanyaki — tailored for each cooking style
  • Hotel & Resort — Centralized systems for banquet halls, all-day dining, room service
  • Food Court & Mall — 60,000+ m³/h modular parallel design for multi-tenant environments
  • Chain Restaurant — Standardized deployment across 100+ locations
  • BBQ & Grill House — ESP + UV-C combination for heavy smoke and intense odors
  • Café & Bakery — Compact, quiet ESP for urban storefronts

Our 100,000+ sqm Smart Factory

Polygee CNC automated ESP production line Polygee ESP product showroom

Our self-owned manufacturing base in Zhangjiagang, Jiangsu is just 2 hours from Shanghai Port. With an annual capacity of 200,000+ ESP units, we deliver consistent quality at any production volume.

  • MES System — Full-chain traceability from raw materials to finished goods
  • CNC Laser Cutting — ±0.1mm dimensional precision
  • Robotic Welding — Automated, consistent weld quality
  • 100% QC Inspection — Every unit tested for high-voltage, airflow, and efficiency before shipment

Global Certifications

CertificationMarket Coverage
ULNorth America (USA / Canada)
CEEuropean Union
RoHSGlobal
CCEP / CQCChina
ISO 9001 / 14001 / 45001Quality / Environment / Safety

Trusted by Landmark Projects Worldwide

From iconic skyscrapers to world-class hotel groups, Polygee ESP systems are installed across five continents.

Taipei 101 with Polygee ESP Marina Bay Sands Singapore ESP Dubai Mall Polygee ESP
Waldorf Astoria Lusail Qatar ESP Jio World Centre Mumbai ESP Solaire Resort Manila ESP
University of Sydney ESP Tun Razak Exchange KL ESP DoubleTree Hilton Sri Lanka ESP

Export Markets

  • Europe — UK, Germany, France, Italy, Spain, Netherlands, Poland, Sweden
  • Middle East — UAE, Saudi Arabia, Qatar, Kuwait, Oman, Bahrain
  • Asia-Pacific — Singapore, Malaysia, Thailand, Vietnam, Philippines, Australia
  • Americas — United States, Canada, Mexico, Brazil

Partner With Us: OEM/ODM & Distribution

Overseas clients inspecting Polygee factory Clients observing ESP assembly line

Whether you want to distribute under the Polygee brand or build your own ESP brand through private-label manufacturing, we have a cooperation pathway ready for you.

What We Offer

  • Custom branding — Your logo, nameplate, and packaging
  • Spec adjustments — Adapted for your market’s voltage, regulations, and installation practices
  • New product co-development — 60+ R&D engineers supporting concept-to-delivery
  • Fast lead time — 7–15 days for standard models; stock inventory available
  • Simple process — Inquiry → Quote (24h) → Sample → Production → FOB/CIF Shanghai
International distributors factory visit Visitors touring production line

Why Choose Polygee

  • BSE-listed (920802) — China’s first A-share listed ESP manufacturer, ensuring financial transparency and long-term stability
  • 179 patents — The deepest IP portfolio in the commercial kitchen ESP industry
  • 100,000+ sqm smart factory — In-house manufacturing with 200,000+ annual capacity
  • Plate-type technology — 90%–99% efficiency, washable cells, 10+ year lifespan
  • UL / CE / ISO certified — Ready for import clearance in 50+ countries
  • 20 years focused — One product category, zero deviation, proven at scale

Ready to Source Quality ESP Systems?

Tell us your kitchen requirements. Our engineering team will design the perfect solution — free consultation, fast response.