Chat on WhatsApp

Get a Free Quote in 24 Hours

Tell us your kitchen airflow and requirements — our engineers will send a sized proposal within one working day.

Get Quote

Electrostatic Precipitator HS Code: Where a Kitchen ESP, ESP Hood and Ecology Unit Sit in the Harmonized System, and What Your Broker Needs to Classify Them

An electrostatic precipitator HS code is the six-digit Harmonized System subheading, extended by each importing country into its own tariff line, under which customs classifies the unit. The HS 2022 text points a complete in-duct unit to 8421.39; search results add codes repeated from past declarations. Describe the unit to your broker and settle the line before the proforma invoice.

This page helps you decide what to send your customs broker, so that an electrostatic precipitator, ESP hood or ecology unit from China can be classified before you order. It also helps you decide whether to ask for an advance ruling first, and whether an ESP hood or a canopy with an in-duct ESP changes the line. It does not give a final code, a duty rate or the full import requirements of any market. For what a quotation from us states, see what an electrostatic precipitator quotation contains. For the documents that travel with the goods, see the ESP pre-shipment inspection.

QuestionOur answer
Who decides the codeCustoms in the importing country, on the declaration your broker makes; an advance ruling makes the answer binding before import
Where the HS 2022 text points for an in-duct ESPSubheading 8421.39, the “Other” line for filtering or purifying machinery and apparatus for gases: the starting point for your broker, not a ruling
An ESP hood with its own fanHeading 84.14 names hoods with a fan, whether or not fitted with filters; subheading 8414.60 covers only hoods with a maximum horizontal side not exceeding 120 cm
Spares and consumables shipped on their ownThey follow their own headings, line by line, in The 8-Line ESP Tariff Classification Sheet
The supplier’s export codeAsk which code it expects to declare for export, or used on an earlier shipment of the same model, and give it to your broker as a reference; it does not bind the importing country
What we send for classificationDatasheets with the dimensions, the model list and the certificate copies for the quoted models; PDFs are emailed within one business day on request
Duty rateNot given here; it follows the line declared and the origin of the goods, and your broker confirms it

Why one electrostatic precipitator turns up under different codes

The codes differ for three reasons. The Harmonized System fixes six digits worldwide, and each country adds its own digits below them. Shipment-record listings repeat whatever was declared, which may be a part rather than a complete unit. None of these codes is a classification of your unit.

The Harmonized System is maintained by the World Customs Organization (WCO). Each commodity group carries a six-digit code, and the WCO states that more than 200 countries and economies use the system as the basis for their customs tariffs. Below six digits, the lines are national. The US and UK tariffs run to ten digits; the Australian tariff runs to eight digits plus a statistical code. The same electrostatic precipitator can share six digits in every market and still carry a different full line in each.

When we searched “electrostatic precipitator hs code” on Google India on 9 October 2026, the first page of results showed at least five different codes. All but 8421.39 appeared only in shipment-record listings; 8421.39 also came up on a tariff-lookup page. A listing repeats what an importer or exporter declared, not what the heading text describes.

Two of those codes show why a listing is a lead, not an answer. In the HS 2022 text of Chapter 85, subheading 8546.20 is electrical insulators of ceramics. In the HS 2022 text of Chapter 84, subheading 8421.99 is the “Other” line under the parts of heading 84.21. An insulator or a spare part declared for an electrostatic precipitator can carry the product name in its description. Neither subheading describes a complete unit.

A dedicated line exists in only some tariffs. Of the national tariffs we read, the US is the only one that names electrostatic precipitators on a line of their own: 8421.39.0120, under “Industrial gas cleaning equipment”. A separate US line covers dust collection and air purification equipment. The UK and Australian tariffs place them under “Other” lines of 8421.39. A request for “the ESP code” therefore has a different answer in each market; the lines are set out under national tariffs below.

Decision rule. IF a code comes from a shipment-record listing, THEN treat it as a lead, BECAUSE a listing shows what was declared, and two of the codes in those listings describe an insulator and a part.

Who decides the code, and on what

Customs in the importing country decides the code. Your broker declares a line on the basis of the heading text, and an advance ruling, where you ask for one, makes the answer binding before the goods arrive. No electrostatic precipitator HS code from the supplier or from a search settles it.

The order in which the text is read is fixed by the General Rules for the Interpretation of the Harmonized System. Rule 1 puts the terms of the headings and the Section and Chapter Notes first; section and chapter titles are for reference only. For machinery, the Section XVI Notes then deal with composite machines, functional units and parts. The WCO’s official interpretation is in the Explanatory Notes, sold by subscription, so your broker may hold them when you do not.

Where an order holds only in-duct ESP units, Rule 1 and the heading text carry the decision; hoods, ecology units and separately shipped spares bring in the other rules.

RuleWhat it says, in our wordsWhere it applies on an ESP order
Rule 1Classification follows the terms of the headings and the Section and Chapter Notes; titles are for reference onlyAn in-duct ESP read against heading 84.21: filtering or purifying machinery and apparatus, for liquids or gases
Rule 2(a)An article presented unassembled or disassembled is classified as the complete articleAn ecology unit whose modules are presented together
Rule 3(a)The heading with the most specific description is preferred to one with a more general descriptionHeading 84.21 against heading 85.43 for an electrical air purifier
Section XVI Note 3A machine performing two or more complementary or alternative functions is classified by its principal functionAn ESP hood, where the broker weighs capture and air movement (84.14) against filtering (84.21)
Section XVI Note 4Components that together contribute to one clearly defined function are classified in the heading for that functionThe three stages of an ecology unit, and a fan supplied with them
Section XVI Note 2A part that is itself a good of a heading goes to that heading; other parts suitable solely or principally for one kind of machine go with that machineA spare power supply; spare collector cells
Rule 6Subheadings are compared only with subheadings at the same level8414.60 against the other subheadings of 84.14, including 8414.59 and 8414.80, once a hood is placed in heading 84.14

These are our paraphrases of the rules; your broker reads the WCO text in full.

Customs can also change its own answer. In ruling HQ 960993 of 1999, the US Customs Service (now US Customs and Border Protection, CBP) classified an air ionizer under heading 84.21 instead of 85.43. It quoted the Explanatory Note to 84.21, which covers filters and purifiers of all types, electrostatic among them, and held 84.21 the more specific heading. It also revoked ruling HQ 082701 of 1988, which had not considered heading 84.21. The subheading numbers in that ruling have since changed; what carries over is the reasoning, not the number.

You can ask for the answer before you order. The WCO describes advance rulings as decisions on classification made before importation, based on legally binding rulings. In the US, CBP issues binding advance rulings, including on tariff classification. In Great Britain, an HMRC Advance Tariff Ruling is a legally binding decision on the commodity code. Elsewhere, ask your broker what the national customs offers.

The code on the supplier’s export declaration is a reference, not a ruling. That declaration is made to Chinese customs, under China’s tariff, and it does not bind the importing country. National tariffs are built on the six-digit HS, so its first six digits can be compared with your broker’s line; the digits after that are China’s own. Ask the supplier which code it expects to declare for export, or used on an earlier shipment of the same model, and pass it on labeled as a reference.

Decision rule. IF this is a first order, an ESP hood with its own fan or a modular ecology unit, THEN ask your broker about an advance ruling before you sign, BECAUSE a ruling binds customs and a search result does not.

The 8-Line ESP Tariff Classification Sheet

For the filtering units on an electrostatic precipitator order, the HS 2022 heading text points to 8421.39. A hood with its own fan brings in heading 84.14, and spares or consumables shipped on their own follow their own headings.

Eight lines cover the items this page deals with: in-duct LK and LK-E units, HME ESP hoods, UV and activated carbon modules, three-stage ecology units, and their spares and consumables. For another model, ask us for its datasheet and describe it to your broker the same way. Each line names where the text points and the rule that decides it. The last column is what your broker needs from you to apply that rule.

The 8-Line ESP Tariff Classification Sheet — our own working sheet, not a customs ruling or an industry standard. It maps eight items on a kitchen ESP order to the HS 2022 text. IF the unit only filters and purifies the exhaust air, THEN the heading text points to 8421.39. IF it is a hood with its own fan, THEN heading 84.14 names it, and the broker decides whether its filtering function points to 84.21. Either way, the importing country’s customs makes the call, through your broker.

#What shipsWhere the HS 2022 text pointsWhat decides itWhat your broker needs from you
1In-duct kitchen electrostatic precipitator (LK, LK-E), with the SPP high-voltage power supply fittedHeading 84.21, filtering or purifying machinery and apparatus for liquids or gases; subheading 8421.39, “Other” under the gases groupRule 1 and the heading text; Rule 3(a) if heading 85.43 is raised, as in US Customs ruling HQ 960993What it does (removes grease and smoke particles from kitchen exhaust air), how (electrostatic charging and collection on stainless steel collector cells), rated airflow, supply and the model list
2HME ESP hood (12 models), which carries its own fan; 1,500 to 2,400 mm long and 1,100 or 1,300 mm deep on the datasheetHeading 84.14 names ventilating or recycling hoods incorporating a fan, whether or not fitted with filters; heading 84.21 comes in only if filtering is found to be the principal functionThe heading text first; Section XVI Note 3 (principal function) if the broker weighs the filtering function; then Rule 6 inside the heading, where 8414.60 asks for a maximum horizontal side not exceeding 120 cmThe largest horizontal dimension from the datasheet, that the fan is built in, and what the hood does first and second: capture, then collection
3UV module (UV30 to UV150), shipped on its ownHeading 84.21, purifying gases, is the first candidate; heading 85.43, electrical machines “not specified or included elsewhere”, is the one weighed against itRule 3(a). A search of CBP’s rulings database found no ruling on a kitchen exhaust UV module; CBP has placed an in-duct ozone purifier with a UV model under 8421.39 (NY R01167, 2004), and HQ 960993 (1999) preferred 84.21 to 85.43 for an ionizerIts place in the duct (after the ESP stage, treating odor in the exhaust air), lamps at 254 and 185 nm, rated airflow
4Activated carbon module (CB), shipped on its ownSubheading 8421.39, filtering or purifying apparatus for gasesRule 1 and the heading textIts function (adsorbing odor compounds from the exhaust air), the medium (coal-based columnar activated carbon), rated airflow
5Kitchen ecology unit: ESP, then UV, then activated carbon; an extract fan can be supplied with itSubheading 8421.39, when the stages together perform one filtering and purifying functionSection XVI Notes 3 and 4 (composite machine, functional unit); Rule 2(a) when the modules are presented together unassembledThe stage list and order, whether the fan is in the supply, that the modules form one unit, and whether they ship in one consignment
6Spare collector cellsSubheading 8421.99, “Other” under the parts of heading 84.21Section XVI Note 2(b), parts suitable solely or principally for one kind of machineThat it is a part, the machine it fits, and its material (stainless steel)
7Spare SPP high-voltage power supply, shipped on its ownA part that is a good of its own heading goes to that heading; heading 85.04, subheading 8504.40 “Static converters”, is the candidate the broker checksSection XVI Note 2(a)Input and output ratings from the nameplate or datasheet, where published, and that it powers the ESP stage
8Consumables shipped on their own: UV lamps; activated carbon refillUV lamps: heading 85.39, subheading 8539.49, “Other” under ultra-violet lamps. Loose activated carbon: heading 38.02, subheading 3802.10Rule 1 and the heading textQuantities, that they are replacements, and whether the carbon is loose or in a filled cartridge; one invoice line for each

This sheet shows where the HS 2022 heading text points for each item we ship. It does not classify your consignment; the importing country’s customs does, through your broker or an advance ruling.

Lines 3, 7 and 8 bring in headings outside 84.21: 85.43 for the UV module, 85.04 for the power supply, and 85.39 and 38.02 for the consumables. The text of heading 85.04, heading 85.39 and heading 85.43 is in the Chapter 85 file linked above; activated carbon is in the HS 2022 text of Chapter 38. Three groups of lines need a decision on your side.

  • Line 2, the hood. The hood question has its own section below, because a hood that carries its own fan is described by two headings at once.
  • Line 5, the ecology unit. Shipping in modules does not by itself split the unit into separate entries when all modules are presented together. Rule 2(a) covers an article presented unassembled, and Section XVI Note 4 covers components that serve one function. Tell the broker the modules form one unit and whether they ship in one consignment. Whether a fan supplied with it belongs to the functional unit or goes on its own line is the broker’s call; say whether it is in the supply.
  • Lines 6 to 8, spares and consumables. Put each on its own invoice line with its own description. A line that reads only “spare parts” gives the broker nothing to classify. On line 8, a filled carbon cartridge is a different article from loose carbon, so say which one ships.
Decision rule. IF a spare or consumable ships on its own, THEN give it its own invoice line and description, BECAUSE Section XVI Note 2 sends such a part to its own heading. IF the ecology unit ships in modules, THEN say so and say whether they travel together, BECAUSE Rule 2(a) speaks of an article presented unassembled.

ESP hood or filter: when heading 84.14 comes into play

Subheading 8414.60 fits only a hood whose maximum horizontal side does not exceed 120 cm. Our HME hoods carry their own fan and run 1,500 to 2,400 mm long on the datasheet. Heading 84.14 names hoods incorporating a fan “whether or not fitted with filters”, so it is the first heading a broker reads for them. Whether the electrostatic cells make filtering the principal function, under Section XVI Note 3, is the broker’s judgment; we found no published ruling on an ESP hood.

A hood for a restaurant kitchen is not excluded for being commercial. In ruling HQ 950295 of 1991, US Customs quoted the Explanatory Note to 84.14. That note includes cooker hoods incorporating a fan for use in the home or in restaurants, canteens and hospitals. The same ruling kept the article in question out of 8414.60 because it did not incorporate a hood. Customs applied the subheading’s words as written.

An ESP hood does two things. It captures the plume at the cookline, and its electrostatic cells collect grease and smoke from the air it draws in. Section XVI Note 3 classifies a machine performing two or more complementary functions by its principal function. A broker who finds filtering to be the principal function would look at heading 84.21 instead of 84.14.

Rule 6 applies only inside the heading chosen. Within 84.14, a hood with a horizontal side over 120 cm falls outside 8414.60. In ruling NY N337346 (2024), CBP placed a 48-inch vent hood with two fans and a filter in heading 84.14 under the fans subheading 8414.59, not under 8414.80 “Other”. Which subheading applies is your broker’s call.

IF the hood has its own fan and a horizontal side over 120 cm, THEN 8414.60 does not describe it. Heading 84.14 still names it, and the broker decides the subheading, or whether filtering points to 84.21.

HoodWhat the HS 2022 text saysWhat to give the broker
Hood with its own fan, maximum horizontal side not exceeding 120 cmHeading 84.14 names it; 8414.60 describes it if 84.14 is the heading chosenThe dimensions from the datasheet, and a statement that the fan is built in
Hood with its own fan, horizontal side over 120 cm (the HME hoods, by the datasheet)8414.60 does not describe it. Within 84.14, CBP has placed such a hood under the fans subheading (NY N337346, 2024); whether its filtering function points instead to 84.21 is the broker’s judgmentThe largest dimension, the fan, and the capture and collection functions in that order
Hood without a fan, feeding an in-duct ESPHeading 84.14 names hoods incorporating a fan; a household range hood shell sold without its blower has been classified as a part of ventilating hoods (CBP NY R04780, 2006, 8414.90), so the broker may also check the parts line 8414.90Describe the hood and the in-duct ESP as separate items, say that the hood has no fan, and let the broker decide; the in-duct unit is line 1 of the sheet

Reading the text against the hood stops short of choosing the heading: that judgment is your broker’s.

The hood is a product decision with a customs side. A project may be able to use either an ESP hood or a plain canopy with an in-duct ESP. The line can differ between the two routes, so ask the broker about both before the route is fixed. The HME dimensions are in the model tables on the ESP hood product page.

Decision rule. IF the hood has a built-in fan and a side over 120 cm, THEN expect the broker to read heading 84.14 first, outside 8414.60, BECAUSE 8414.60 stops at 120 cm.

What national tariffs add below the six digits, and what the line triggers at import

Each country splits 8421.39 its own way: of the tariffs we read, only the US names electrostatic precipitators, on an industrial gas-cleaning line. The line your broker declares is also what import permits, standards marks and duty attach to.

IF you import into a market below, THEN hand your broker the line we read as a starting point, to be confirmed in the current tariff.

TariffLine read for an in-duct ESP or ecology unitHood lineRead on
United States: Harmonized Tariff Schedule of the United States, 2026 Revision 20Two candidate statistical lines under 8421.39.01 “Other”: 8421.39.0120, “Electrostatic precipitators”, listed under “Industrial gas cleaning equipment”, and 8421.39.0115, “Other”, listed under “Dust collection and air purification equipment”. CBP ruling NY N338026 (2024) placed air purifiers in 8421.39.0115; your broker decides which one describes a kitchen exhaust ESP8414.60.0000, “Hoods having a maximum horizontal side not exceeding 120 cm”9 October 2026
United Kingdom: UK Integrated Online Tariff8421 39 25 90, “Other”, under “Machinery and apparatus for filtering or purifying air”; no line names electrostatic precipitators8414 60 00 00, with the same 120 cm wording9 October 2026
Australia: ABF Working Tariff, Chapter 848421.39.90, “Other” (statistical code 16)8414.60.00 (statistical code 04)9 October 2026
Turkey: GTİP, as read on our Turkey page8421.39.25.90.00 is row 10 of Annex 2/A to the 2026 machinery import-inspection communiqué (2026/32); goods on that line need an import inspection pre-permit (TAREKS)8414.60.00.00.00 appears on the 2026/9 list for household hoods onlyOfficial texts read 6 October 2026
Mexico: TIGIE and Annex 2.4.1, as read on our Mexico page8421.39.99 with NICO 02 is listed under NOM-003-SCFI-2014 only for air purifiers designed exclusively for household extraction hoods8414.60.01, household hoods, under the same NOMOfficial texts read 6–7 October 2026
European Union: TARICNot read here; ask your broker to read the line in TARICNot read hereNot read
India, China, Singapore, GCC statesNot read here; the official tariff pages did not give us the line textNot read hereNot read

This table gives the lines as printed on the dates shown. It does not give duty rates, which follow the line and the origin of the goods and can change with trade agreements. Ask your broker for the duty and import taxes on the line before you compare a landed cost. Whether a certificate of origin can lower the rate on the line, and at which ports no form changes it, is set out in our electrostatic precipitator certificate of origin guide.

Reading the line is half the job; the other half is what it triggers. In the Turkey and Mexico rows, the permit or the mark attaches to the declared line, and each country page sets out the steps. The hood and purifier lines on those two lists are household lines, which does not show that a commercial unit is free of requirements. A unit declared under 8421.39.25.90.00 in Turkey is on the machinery pre-permit list. Which line a commercial unit is declared under is your broker’s classification.

The words on the invoice are part of what the broker classifies. A description that reads only “air purifier” or “range hood” invites a broker to look at household lines. Name the use, commercial kitchen exhaust, and the principle, electrostatic precipitation, as the next section does.

The text itself changes on 1 January 2028, when the HS 2028 edition enters into force. We searched the published amendment text, and it does not change headings 84.14 or 84.21. National lines can still be renumbered when tariffs move to the new edition. For goods declared from 2028, have your broker read the line again in the tariff in force on that date.

Decision rule. IF the declared line triggers a permit or a standards mark, THEN start that process once the line is settled, BECAUSE the permit or mark attaches to the line, as in the Turkey and Mexico rows.

What to send your broker: the ESP Broker Description Block

Send a description the broker can classify without seeing the unit. It covers what the unit does, how it works, whether it has a fan, its largest horizontal dimension, its stages, its airflow and supply, and the model numbers on the proforma invoice. The supplier’s export code goes in last, labeled as a reference.

ESP Broker Description Block: nine fields to copy into the email to your broker, filled from the proforma invoice and the datasheet. IF a field cannot be filled from those two documents, THEN ask the supplier for it before the broker classifies, BECAUSE each field answers one of the rules above.

#FieldWhat to writeWhich question it answers
1Commercial descriptionThe plain name and the use: commercial kitchen exhaust electrostatic precipitator, in-duct; ESP hood with built-in fan; three-stage ecology unitWhich heading the words describe (Rule 1); it keeps the goods away from household lines
2What it does, in one sentenceRemoves grease and smoke particles from kitchen exhaust air; on an ecology unit, the UV and carbon stages treat odorFiltering or purifying gases (84.21), or moving air (84.14)
3Operating principleElectrostatic charging and collection on stainless steel collector cells; UV lamps at 254 and 185 nm; activated carbon adsorption84.21 against 85.43 (Rule 3(a))
4FanNone; built in (ESP hood); or supplied with the ecology unitWhether heading 84.14 is in play
5Largest horizontal dimensionFrom the datasheet, in mmWhether 8414.60, at 120 cm, can describe a hood
6Stages, and how it shipsThe stage list in order; assembled, or in modules forming one unit; one consignment or severalSection XVI Notes 3 and 4; Rule 2(a)
7Rated airflow and supplym³/h; voltage, frequency and phase as configured on the proforma invoiceTies the model to the datasheet; national lines can turn on technical detail, as the UK line 8421 39 15 00 and the Australian line 8421.39.10, both defined by a stainless steel housing and tube bores not exceeding 1.3 cm, show
8Model numbers and certificatesModel numbers exactly as on the proforma invoice, and the certificate copies that name themTies the description to the goods and to any import-permit file
9Supplier’s export codeThe code the supplier expects to declare for export, or used on an earlier shipment of the same model, labeled “reference only”A six-digit cross-check, not the import line

The block feeds the broker’s decision without making it; an advance ruling is what makes a line binding.

A hood description, worked through. Field 1: commercial kitchen exhaust hood with built-in electrostatic precipitator cells and a built-in fan. Field 2: captures cooking fumes at the cookline and removes grease and smoke particles from the extracted air. Field 4: fan built in; field 5: 2,400 mm, from the datasheet for HME2400W13, listed at 2,400 × 1,300 × 977 mm. Field 7: 4,800 m³/h at 380 V, 50 Hz, as listed on the datasheet.

Field 5 alone takes 8414.60 off the table; heading 84.14 still names the hood, and the broker decides the subheading or whether filtering points to 84.21.

Worked example from the published HME datasheet — not a classification, a broker’s opinion or a customs ruling.

Fields 1 to 8 come from the proforma invoice and the datasheet. Our quotations include the datasheet and the certificate copies for the quoted models, as listed on our quotation page. Row 8 of the inputs on that page names the importer of record, which is where your broker comes in.

Certificate copies travel with the shipping documents, as listed on our electrostatic precipitator supplier profile, and each covers only the models it names (see our ESP certifications page). Put the description and the line your broker settled on the commercial invoice; checking the copies against the shipped models is row 9 of the ESP pre-shipment inspection.

Whether the factory behind those documents is the manufacturer is a separate check. The steps, from the business license to the certificate holder, are in how to verify a Chinese ESP manufacturer.

Decision rule. IF your broker’s line differs from the supplier’s export code, THEN declare the broker’s line and record why, BECAUSE the export declaration does not bind the importing country.

Scope and limits

Settling the code clears only the first of three layers, and each layer clears on its own.

  • Layer one, classification: the heading text, the rules, the national line and your broker’s declaration or an advance ruling. This layer does not show that an import permit, a standards mark or a label requirement is met. Take the line your broker settled and check what it triggers in your market; Turkey and Mexico above are two examples.
  • Layer two, import requirements: permits, conformity assessment, labeling, duty and taxes. This page does not cover them. Ask your broker to confirm them in writing before the proforma invoice is signed.
  • Layer three, the site: installation, electrical inspection and any discharge permit. These belong to the project and the local authority. Hand them to your contractor and keep them in a separate record from the classification.

Passing one layer does not clear the next. This page covers layer one only.

  • No duty rate is given. It follows the line and the origin of the goods; your broker confirms it.
  • No final code is given for any item. The sheet shows where the text points; customs decides.
  • No national line is given for the EU, India, China, Singapore or the GCC states. Ask your broker to read it in the national tariff.
  • The Explanatory Notes are quoted only as US Customs quoted them in 1991 and 1999. The current text is sold by the WCO by subscription; your broker may hold it.
  • No published CBP ruling on a commercial kitchen ESP or ESP hood was found. The nearest concern hoods (NY N337346, NY R04780, HQ 950295) and air purifiers or ionizers (NY N338026, NY R01167, HQ 960993). They are cited for their reasoning, not as rulings on your goods.
  • From 1 January 2028 the HS 2028 edition applies. Have the line read again for goods declared from that date.

Buyer record and key takeaways

Five lines go into the project file with the quotation.

  • Before you ask for a quotation: the destination country, the importer of record and the broker who will declare the goods.
  • Send your broker: the ESP Broker Description Block, filled from the draft proforma invoice and the datasheet, with the line of The 8-Line ESP Tariff Classification Sheet that each item belongs to.
  • Ask the supplier for: the datasheets with the dimensions, the certificate copies that name the quoted models, and the code it expects to declare for export, or used on an earlier shipment of the same model, as a reference.
  • Ask your broker for: the line, the duty and taxes on it, what it triggers at import, and whether an advance ruling is worth applying for.
  • Re-check when: the destination changes, a model changes, a hood with a fan replaces a canopy, the ecology unit ships in modules instead of assembled, or the goods are declared on or after 1 January 2028.

Key takeaways

  • Source: an electrostatic precipitator HS code comes from the heading text and the rules, not from a code repeated in a shipment-record listing.
  • Who decides: the importing country’s customs, through your broker or an advance ruling, not the supplier’s export declaration.
  • In-duct units: The 8-Line ESP Tariff Classification Sheet points them to 8421.39 at six digits, not to one ten-digit code valid in every market.
  • Hoods: a fan hood with a side over 120 cm is outside 8414.60 but still named by heading 84.14; the text decides, not the word “hood”.
  • Spares: separately shipped spares and consumables follow their own headings, not the unit’s line.

Frequently asked questions

What is the HS code for an electrostatic precipitator?
The HS 2022 heading text points a complete in-duct unit to subheading 8421.39, filtering or purifying apparatus for gases, but the importing country’s customs decides the final line. There is no single code for every market. The US tariff names electrostatic precipitators on line 8421.39.0120, under “Industrial gas cleaning equipment”. It also has an air-purification line, 8421.39.0115, so your broker chooses between them. The UK and Australian tariffs place electrostatic precipitators under “Other” lines; ask your broker to confirm the line in your own tariff.
Is an ESP hood classified under 8414.60?
Only if heading 84.14 is chosen and the hood’s maximum horizontal side does not exceed 120 cm. A hood with its own fan that is longer than that is outside 8414.60. Heading 84.14 still names hoods with a fan whether or not fitted with filters, and the broker decides the subheading, or whether the filtering function points to 84.21. Give the broker the largest dimension from the datasheet, and state that the fan is built in.
Can I use the HS code on the supplier’s export declaration?
Use it as a reference, not as the import line. The export declaration is made to Chinese customs and does not bind the importing country. Its first six digits can be compared with your broker’s line; if they differ, declare the broker’s line and record why.
Do spare parts and UV lamps go under the same code as the unit?
Not when they are shipped on their own. A part that is a good of its own heading goes to that heading. A spare power supply is checked against 8504.40, UV lamps against 8539.49 and loose activated carbon against 3802.10. Spare collector cells point to the parts line 8421.99. Put each on its own invoice line.
Can the code be confirmed before I order?
Yes, through an advance ruling where the importing country offers one. CBP in the US and HMRC in Great Britain issue binding rulings on classification before import. Ask your broker whether a ruling is worth applying for on a first order, an ESP hood with its own fan or an ecology unit shipped in modules.

Ready to brief your customs broker?

Classifying an electrostatic precipitator or ecology unit order for import? Send us the destination country and the models on your quotation. You get back the datasheets with the dimensions and the certificate copies that name those models: the material for fields 1 to 8 of the ESP Broker Description Block. With them, your broker can place each item on The 8-Line ESP Tariff Classification Sheet and settle the line.

Still preparing the inquiry? Start from the ten inputs on our electrostatic precipitator quotation page: row 8 names the importer of record, and the broker’s line follows from there.

Send the destination and models →

Why we write this. We prepare the documents an importer’s broker works from. Buyers at that point search for the HS code for an electrostatic precipitator or a kitchen hood, and ask who decides the code and whether the export-declaration code can be used. This page answers both from the published tariff texts and lists what to send the broker. This guide does not size or configure equipment; sizing and quotation live on the product pages.

S
Written by Scarlett · Business Director, Polygee

Scarlett handles orders at Polygee from the proforma invoice to the shipping documents, along with export inquiries, dealer relationships and commercial terms. Polygee, founded in 2004, manufactures the in-duct electrostatic precipitators, ESP hoods and ecology units described here and has exported to 50 countries. This page reads published tariff texts; it is not a customs ruling, a broker’s classification or legal advice.


References & further reading

  1. World Customs Organization, What is the Harmonized System (HS): six-digit codes, used by more than 200 countries and economies as the basis for their customs tariffs; the Explanatory Notes as the official interpretation, by subscription. wcoomd.org (what is the HS)
  2. World Customs Organization, HS Nomenclature 2022 Edition: General Interpretative Rules; Section XVI Notes; Chapter 84 (headings 84.14 and 84.21); Chapter 85 (headings 85.04, 85.39, 85.43, 85.46); Chapter 38 (heading 38.02).
  3. World Customs Organization: HS 2028 amendments, effective 1 January 2028, and the amendment text (NG0304Ba) searched for headings 84.14 and 84.21; Advance rulings for classification.
  4. National tariffs, read 9 October 2026: US International Trade Commission, Harmonized Tariff Schedule (2026 Revision 20); UK Integrated Online Tariff, 8421 39 25 90 and 8414 60 00 00; Australian Border Force, Working Tariff, Chapter 84; European Commission, TARIC consultation (where to look; not read here). The Indian customs tariff (CBIC) and the Chinese customs tariff are named, not linked: their line text was not read.
  5. US Customs and Border Protection, rulings database (the 1991 and 1999 rulings were issued by the US Customs Service): HQ 960993 (1999), air ionizer, heading 84.21 preferred to 85.43; HQ 950295 (1991), Explanatory Note to 84.14 on cooker hoods incorporating a fan; NY N337346 (2024), 48-inch vent hood with two fans and a filter, heading 84.14, subheading 8414.59; NY R04780 (2006), range hood kit without blower, parts line 8414.90; NY N338026 (2024), air purifiers, 8421.39.0115; NY R01167 (2004), in-duct ozone purifier with UV and corona-discharge models, 8421.39; Rulings and legal decisions.
  6. HM Revenue & Customs: Apply for an Advance Tariff Ruling (GOV.UK, updated 2 June 2026).

Related reading