Electrostatic Precipitator Supplier for Turkey Projects: Two Product Routes, the CE File and TAREKS, 230/400 V Supply, Why the Filter Does Not Replace the Flue, and What to Send for a Quote

An electrostatic precipitator for a Turkish commercial kitchen, sold locally as an elektrostatik filtre or elektrostatik baca filtresi, is an in-duct unit, or a hood with the cells built in, that charges grease and smoke particles and collects them on washable plates. Polygee supplies the electrostatic precipitator Turkey kitchen projects fit from its factory in Zhangjiagang, China, with a minimum order of one unit and a 7–15 day lead time.

This page helps you decide whether a factory-direct electrostatic precipitator suits your Turkish project, which route to price, which models the CE certificate names, what the importer has to arrange before the goods clear, and why the filter does not settle the flue question. It does not size a unit, quote a price, classify goods for customs or grant a license. For model tables, see the LK in-duct range and the HME ESP hood; for what sets the number, see what sets an electrostatic precipitator price.

QuestionOur answer
Supplied in Turkey before?Turkey is on our shipped list, on the European line; no Turkish installation is published, and this page does not name one
Minimum order and lead timeOne unit; 7–15 days as standard, with freight to your port quoted with the Incoterm
Two routesAn in-duct LK or LK-E unit, the elektrostatik filtre behind any hood, from 2,000 m³/h per unit; or an HME ESP hood, a davlumbaz with the cells and the fan inside, in twelve models
Site supply50 Hz, which matches the brochure input; state 230 V single-phase or 400 V three-phase as measured, and the offer names the 220 V or 380 V build supplied for it
CE certificateFQC2602501, against the Machinery, EMC and Low Voltage directives, naming LK30–LK480, LK30E1–LK150E1 and the UV series; match the offered model numbers against it
ImportThe importer confirms the CE marking and documents, puts its name on the equipment and supplies Turkish instructions; if the unit is declared under GTİP 8421.39.25.90.00, a TAREKS pre-permit and a declaration approved in China come first
FlueAs we read them, the national license, fire and zoning texts require a flue for a restaurant kitchen and make no exception for a filter; the unit cleans what goes up the flue
Incoterm and portCIF to Ambarlı, Mersin or the port your forwarder clears at; FOB or EXW when they book the sea leg
WarrantyOne year on the complete unit; UV lamps and carbon media, where fitted, are consumables

Shipped to Turkey, and what a shipping record does not settle

Turkey is on the list of countries we have shipped Polygee units to. Our supplier profile carries it on the European line, next to the UK, Germany, Italy, Spain and the Netherlands. No Turkish installation is on the published project record, and this page does not name one. That leaves a narrow fact: units built in Zhangjiagang have been shipped to Turkey before. It says nothing about how a unit behaves on your cooking line, and it is no substitute for the test report on the model you are offered.

RecordWhat it showsWhat it does not show
Turkey on the shipped listFactory-direct units have been shipped to Turkey beforeWhich port, which route, which importer, or how those units perform
Published project recordNo Turkish site is named—
Third-party test report for the series offeredThe result under the stated test conditionThe result at your discharge, which follows your cooking load, airflow, hood capture and cleaning

This table answers what the record is. It does not answer whether a unit will meet your consultant’s brief; that is settled by the configuration, the test report and the site, in that order.

Decision rule. IF a vendor assessment asks for a Turkish reference, THEN record that Turkey is on our shipped list and that no Turkish site is published, BECAUSE a name we cannot show you is worth less than a report you can check. IF the assessment asks for performance evidence, THEN request the third-party report for the series offered and read which model it tested and under what condition, BECAUSE that is the document that speaks to performance.

Two product routes, and the Turkish names that pick them

Turkish suppliers sell this equipment under several names, and matching each name to a route saves a round of quotations. An elektrostatik filtre or elektrostatik baca filtresi is the electrostatic stage itself, the part that collects grease and smoke particles. Our LK and LK-E units are exactly that, installed in the extract duct behind the hood. A davlumbaz is the hood over the cooking line, and our HME range is a davlumbaz with the electrostatic cells and the fan built in. Local offers that pair an electrostatic filter with UV-C and activated carbon describe what a consultant’s drawing calls an ecology unit. That is the in-duct route with odor stages behind the electrostatic stage, set out in eight sizes on the kitchen ecology unit page. We make all three. The choice follows the duct route, the cooking line and whether the brief names an odor condition.

RouteWhat it isBetter fit whenMain limitationWhat it means for your quote
In-duct LK or LK-E unit (elektrostatik filtre)An electrostatic precipitator mounted in the extract duct downstream of any hood; single units from 2,000 m³/h, scaled in parallel; the LK-E series in three tiers at or above 90, 95 and 98 percent design efficiency, 33 modelsA shopping-mall food court or a hotel kitchen sends several hoods into one extract; the hood is made locally; an odor stage may be added in the same run now or laterNeeds straight duct length and access on one side for washing the cellsPrice the unit and, separately, the duct adapters your contractor supplies; say whether UV-C or carbon stages are in scope; match the offered model numbers against the CE certificate
HME ESP hood (davlumbaz with the stage built in)A canopy with the electrostatic cells and the fan built in; twelve models; brochure input 380 V, 50 HzA single cooking line; a street-front restaurant with no ceiling void for an in-duct unit; the hood and the filtration are wanted from one makerOne hood, one line; larger extract rates mean more hoods rather than a bigger unitPrice by hood length and cooking line; the fan is inside the hood; ask which conformity documents the offer lists for the hood model; in a shopping center, a high-rise or a kitchen serving more than 100 people at once, the automatic extinguishing system the fire regulation requires on the hood goes to your fire contractor

The table picks the route, not the model. The model follows the extract rate and the cooking load, and the offer names it.

An electrostatic filter does not replace the flue

Some vendor pages in Turkey sell the electrostatic filter as a way to open a restaurant bacasız, without a flue, or to clear a license held up by the flue. We do not make that claim for our units, because the national texts do not support it. The regulation on workplace opening and operating licenses, the İşyeri Açma ve Çalışma Ruhsatlarına İlişkin Yönetmelik, requires a flue system in the food preparation and cooking area to carry away the steam, odor and smoke it produces. Article 88 of the fire protection regulation for buildings requires the mechanical exhaust of hotel, restaurant and cafeteria kitchens to be independent of the building’s other systems; the exhaust must discharge directly outdoors, at least 5 m from any air intake. Article 33 of the national zoning regulation requires at least one extractor flue in the kitchen of every independent unit. None of the three makes an exception for a filter. The one text we found that does is local: since a 2025 amendment, Article 35 of Gaziantep’s zoning regulation allows a standards-compliant flueless filtered extractor in the kitchens of independent units. It does not single out restaurants, and it does not travel: Istanbul’s zoning regulation keeps the national wording.

What an electrostatic precipitator changes is what leaves the flue. The grease and smoke particles it collects stay on the plates of the cells instead of on the roof, the facade or the neighbor’s windows. That is the case to make to a municipality that has received complaints. Where the cleaned air may discharge is a different decision, taken by the municipality and drawn by your consultant. We quote on the basis of a ducted discharge to the point the consultant designs.

TextWhat it requiresException for a filter?What it means for the ESP order
Workplace license regulation, Annex 1, common conditions, item 6A flue system in the food preparation and cooking area for steam, odor and smokeNone in the textThe unit sits in that flue system; it does not stand in for it
Fire protection regulation, Article 88(2)Restaurant kitchen exhaust independent of other systems, discharged directly outdoors, at least 5 m from any air intake, with no fire dampers in the kitchen exhaust ductNone in the textThe duct, its fire protection and the discharge point are your contractor’s design
Fire protection regulation, Article 57(1)An automatic extinguishing system on the hoods of kitchens in shopping centers, high-rise buildings and food factories, and of kitchens serving more than 100 people at once, with gas detection and shut-offNot applicableAn HME hood in one of those kitchens is coordinated with the extinguishing installer
National zoning regulation, Article 33(10)At least one extractor flue in the kitchen of every independent unitNone in the text—
Gaziantep zoning regulation, Article 35(10), as amended in 2025Allows a standards-compliant flueless filtered extractor in the kitchens of independent unitsYes, locally; not specific to restaurantsAsk the municipality in writing before relying on it, and send us the answer
Regulation on odor-causing emissions (2013)Covers the activities listed in the annexes of the environmental permit regulation; restaurants are not among them, as we read the annexesNot applicableIt does not set the odor brief for a restaurant; your consultant or the municipality does

These are the national texts as we read them. What a particular municipality accepts on a particular building comes from the municipality, in writing, through your consultant.

Decision rule. IF a supplier tells you a filter lets the restaurant skip the flue, THEN ask which municipal provision allows it and get the municipality’s answer in writing before you order, BECAUSE the national license, fire and zoning texts we read require a flue and make no exception for filters. IF your municipality does have such a provision, as Gaziantep’s does for kitchens of independent units, THEN send it with the municipality’s written answer, BECAUSE your consultant has to show it applies to a commercial kitchen, and we quote on a ducted discharge either way.

What a factory-direct order covers in Turkey, and what stays with your contractor

The order from us is the equipment, its documents and remote support from the factory. Three groups of work stay in Turkey. Your mechanical contractor installs, ducts and commissions, and runs the flue to the discharge point the consultant draws. Your importer of record declares the goods, itself or through a customs broker, the gümrük müşaviri, and answers any import inspection. Your consultant and the municipality decide what the installation has to show before the license is granted. Agree an owner for every line of the table before you compare offers; a line that one offer leaves out does not vanish, it reappears on somebody else’s invoice.

ItemFactory-direct from PolygeeYour Turkish contractor, importer or consultantWhat it means for your quote
In-duct unit or ESP hood, with the high-voltage power supply and control gearSupplied in the 220 V or 380 V build named for the stated site supply—The part every offer should price the same way, so state the route, the airflow and the supply
UV-C or activated carbon stage, where an odor condition calls for itAvailable as modules in the same run—Say whether an odor stage is in scope; two offers with different stage lists are not comparable
Extract fanInside an HME hood; available with an in-duct unit, selected on the total static pressure of the runUsually in the mechanical package for in-duct installationsSay which you want, or the offer that includes a fan will read as the more expensive one
Ductwork, the flue to its discharge point, transition pieces, attenuators and the fire protection of the ductNot suppliedYesAdapter and flue work left unstated turns into a variation after the order
Automatic extinguishing on the hood, gas detection and shut-off, where Article 57 of the fire regulation appliesNot suppliedYour fire contractorCoordinate the hood drawing with the installer before the order
Supports, hangers and structural workNot suppliedYesAsk for module and hood weights with the offer
Installation labor and commissioning attendanceNot included; paid on-site service is availableYesPrice installation locally against our drawings
Turkish-language instructions and safety informationThe English manual, drawings and specification sheets as the source textThe importer of record arranges the Turkish versionAgree who translates before shipment, so the units are not held for a missing manual
Customs declaration, import inspection where the declared line calls for one, duties and taxesCommercial invoice, packing list and the certificate references on themThe importer of record, itself or through its brokerA consignment with no importer named cannot be declared
Submissions to the municipality, the fire authority or the design consultantDocuments prepared against the reviewer’s listThe submission itselfA late request delays approval, not delivery
Spare parts and consumablesCommon spares held in stockDecide the holding you wantQuote them with the unit, so the first order is budgeted

This table answers who supplies what. It does not answer what any of it costs; that follows the route, the airflow and the configuration.

Commercial terms, stated up front

The table keeps to the lines a Turkish destination changes. Payment, Incoterms, spares, remote support hours, OEM branding, the NDA and the pre-shipment inspection apply to every order the same way. They sit on our electrostatic precipitator supplier profile, where you can hold any offer against them, ours included.

TermWhat applies to a Turkish orderWhat it means for your project
Site supplyA 220 V single-phase or 380 V three-phase build, named against the voltage measured at the panel; 50 Hz needs no changeState the measurement, not a nominal figure copied from a regulation
Incoterm and portCIF to Ambarlı, Mersin or the port your forwarder clears at; FOB or EXW when they book the sea legName the port and the Incoterm; the proforma invoice is priced on that basis
Clearance partyThe importer of record declares the goods, itself or through its broker, and answers any import inspection on the line it declaresBoth are Turkish parties; agree who they are before the proforma invoice
Conformity documentsCE certificate FQC2602501 for the models it names, the RoHS certificate for the lines it names, the ISO certificates, the third-party test reports for the series offered, each naming the model tested, general arrangement drawings and specification sheetsSend the importer’s and the reviewer’s lists early; the Turkish instructions are the importer’s to arrange
Minimum order and lead timeOne unit; 7–15 days as standardA single trial unit is a normal first order; freight time, and any pre-permit time, are added on top
WarrantyOne year on the complete unit; UV lamps and activated carbon media, where fitted, are consumables and are not coveredBudget consumables separately when an odor stage is in scope
Everything elsePayment, Incoterms, spares, remote support hours, OEM branding, NDA and factory inspectionRead them on the supplier profile; they do not change for Turkey

Price is the one term missing. The route, the airflow and the configuration set it, as explained in what sets an electrostatic precipitator price.

Site power: 230/400 V and 50 Hz

Turkey runs at 50 Hz. Article 7 of the grid regulation, the Elektrik Şebeke Yönetmeliği, fixes the nominal system frequency at 50 Hz and has the transmission operator, TEİAŞ, hold it between 49.8 and 50.2 Hz. That is the frequency of our brochure input: 220 V, 50 Hz for in-duct units, with 380 V three-phase configured to order, and 380 V, 50 Hz for HME hoods. A Turkish order therefore carries no frequency change. Expect 230 V between phase and neutral and 400 V between phases. No regulation in force states that figure outright, but the Ministry of Energy’s earthing regulation works its TN-system table on U0 = 230 V, 50 Hz. How far the supply may move is EPDK’s business. Its distribution quality regulation leaves the limits to a Board procedure, which applies TS EN 50160:2011 and expects low-voltage measurements to stay within 10 percent either way. None of this replaces a measurement. Write down the voltage and the phase count at the panel that will feed the unit, 230 V single-phase or 400 V three-phase. The offer then names the build supplied for it, 220 V single-phase or 380 V three-phase, the configurations we publish.

Site factWhere to read itWhat to state in the enquiry
FrequencyThe grid regulation’s 50 Hz, held between 49.8 and 50.2 Hz“50 Hz”; no configuration change follows
Voltage and phaseThe switchboard schedule and a measurement at the panel feeding the unit230 V single-phase or 400 V three-phase, as measured; the offer names the 220 V or 380 V build supplied for it
Isolator position and feeder routeThe electrical contractor’s drawingsNothing on the unit; it decides whether the access side of the run, or the hood’s service side, stays clear

This table answers what to state about the supply. It does not answer whether the feeder is adequate; that check belongs to your electrical contractor, against the electrical data on the specification sheet.

Import: the CE file, TAREKS and the Turkish instructions

Turkey reads the CE marking the way the EU does. The EU–Türkiye Customs Union covers all industrial goods and commits Turkey to align its technical legislation with the EU’s. The Turkish regulation on electrical equipment for use within certain voltage limits (2014/35/AB) follows the Low Voltage Directive. Under its Article 8 the manufacturer draws up the technical file and the declaration of conformity and affixes the CE marking. Under Article 10 the importer confirms all of that before placing the equipment on the market. Our CE certificate FQC2602501, issued against the Machinery, EMC and Low Voltage directives, names the LK series LK30–LK480, the LK-E1 models LK30E1–LK150E1 and the UV series. The useful check is the one a careful importer makes anyway: hold the model numbers in the offer against that list before the proforma invoice is issued.

Article 10 also gives the importer two jobs that are better scheduled than discovered at the port. The importer’s name, registered trade name or mark and a contact address go on the equipment, or, where that is not possible, on its packaging or an accompanying document. The instructions and safety information travel in Turkish or in a language the Ministry accepts; the EMC regulation and Law No. 7223 on product safety and technical regulations ask for Turkish outright, so plan on Turkish. Article 15 adds that a declaration of conformity drawn up in another language is translated into Turkish as well. Our part is the source text, the English manual, the specification sheets and the drawings; tell us at order stage if the importer’s details should go on the packing marks.

Then comes the import inspection. The Ministry of Trade runs TAREKS, a web-based, risk-based control system, and publishes each year the tariff lines that must pass through it. For 2026 the machinery list is the communiqué on the import inspection of machinery (2026/32). Row 10 of its Annex 2/A is GTİP 8421.39.25.90.00: other machinery and apparatus for filtering or purifying gases, excluding those used in motor vehicles. Goods on that annex need an import inspection pre-permit before the inspection application is made. TSE carries out the inspection before the customs declaration is registered. The EU declaration of conformity uploaded to TAREKS must also carry the approval of Turkey’s commercial counselor or attaché in the country of departure, with a certified Turkish translation. If the importer’s broker declares the unit under that line, this is the route. The approval has to be obtained in the country of departure, China, so plan it at order stage and tell us which of our documents the importer needs for it. Which line applies is the broker’s classification, not ours. The hood line in the companion list for CE-marked products, communiqué 2026/9, covers household hoods no wider than 120 cm, which does not describe a commercial ESP hood. Where the declared line is on either list, the importer enters the TAREKS reference in box 44 of the customs declaration. The communiqué is explicit that permission to import does not mean a product is compliant or safe.

The declaration itself belongs to the importer. The Ministry of Trade’s customs guidance says a trader may lodge its own declarations or appoint a customs broker, and that using one is not compulsory. Duties and taxes are the importer’s to confirm at quotation; ask your broker which packing documents they need and put them in the enquiry.

StepWho does itWhat we supply
Name the importer of record, and its customs broker if it uses oneYou, or your contractorThe proforma invoice, issued to the importer
Classify the goods (GTİP) and check the line against the 2026 import inspection communiquésThe importer, or its brokerThe tariff description and the technical data of the offered configuration
Where the line is in Annex 2/A of 2026/32: apply for the import inspection pre-permit through TAREKSThe importerOur share of the documents the application lists
Have the EU declaration of conformity approved by Turkey’s commercial counselor in the country of departure, with a certified Turkish translationObtained in China, the country of departure, as the importer arrangesOur documents that the importer names for the approval, planned at order stage
Confirm the CE marking and documents, put the importer’s name on the equipment and supply Turkish instructionsThe importerCE certificate FQC2602501 for the models it names; the English manual and drawings as source text
Lodge the customs declaration, with the TAREKS reference in box 44 where the line is listedThe importer, itself or through its brokerCommercial invoice, packing list and the certificate references on them
Decision rule. IF the broker declares the unit under GTİP 8421.39.25.90.00, THEN put the pre-permit and the counselor’s approval of the declaration into the schedule with the proforma invoice, BECAUSE the approval has to be obtained in China, the country of departure, and the TAREKS application waits for it. IF the broker uses another line, THEN record which one and why in the enquiry, BECAUSE the inspection route follows the declared line, not the product’s name.

Ambarlı, Mersin and the Incoterm

Istanbul and Marmara projects land at Ambarlı, the port complex where the Marport container terminal operates. Marport describes the location as placed to serve West Marmara, where industrial and manufacturing activity is very dense. Projects in the south and southeast go through Mersin. PSA International, the group behind Mersin International Port, calls it Türkiye’s largest and most advanced port and the primary gateway for southern Türkiye and the eastern Mediterranean. Its hinterland takes in Adana, Gaziantep, Kayseri and Konya. On the Aegean, SOCAR Terminal at Aliağa describes itself as the largest logistics center in the region; in Bursa, Gemport at Gemlik describes itself as the main sea gateway for the region’s industry. A CIF quotation names the destination port to which we pay the freight and insurance; a FOB or EXW quotation hands the sea leg, and the port question, to your forwarder. Transit time is the one figure this page cannot give you. Ask for it with the proforma invoice, add it to the 7–15 day lead time and to any pre-permit time, and check the total against your on-site date.

Project regionUsual gatewayWhat to write in the enquiry
Istanbul and West MarmaraAmbarlı“CIF Ambarlı”, and who clears at the port
BursaGemlik“CIF Gemlik”, and who clears at the port
Adana, Mersin, Gaziantep and the south and southeast; Kayseri and KonyaMersin“CIF Mersin”, and who clears at the port
İzmir and the AegeanAliağa, or the port your forwarder clears at“CIF” with that port named, and who clears there
Ankara and elsewhereThe port your forwarder clears at“CIF” with that port named, or “FOB” or “EXW” with your forwarder’s details

Transit time and clearance costs are not in the table. Your forwarder and your broker supply both.

Documents for the importer, the consultant and the municipality

In a market that reads the CE marking, the document pack does more work than elsewhere, so know what each item carries before it reaches a reviewer. We put the pack together against the list your importer and your consultant issue: certificates, third-party test reports, general arrangement drawings and specification sheets. Approvals stay with the project. The municipality, the fire authority and the consultant judge the installation on the project’s own submission, and nothing in the pack is an approval of it.

DocumentWhat it supportsWhat it does not prove on its ownWhat to check
CE certificate FQC2602501 (Machinery, EMC and Low Voltage directives)Conformity of the models it names: the LK series LK30–LK480, the LK-E1 models LK30E1–LK150E1 and the UV seriesCoverage of any model not named on it; the installation’s approval, which belongs to the municipality and the consultantMatch every model number in the offer against the certificate
RoHS 2.0 certificate BKC25114877LCRestricted-substance compliance for the lines it names, the LK, LK-E and HME series among themCoverage beyond the lines it names; electrical safety of any kindThe same model-number check
ISO 9001, ISO 14001 and ISO 45001 certificates (ABZB25Q30072R3M, ABZB25E30043R3M, ABZB25S30027R2M)The management systems the factory works underThe performance of any particular unitAsk for copies with the pack
Third-party test report ZY05W230298 (CMA-accredited)Grease removal of up to 97.6% on LK units at rated, evenly distributed airflow, under that testAn odor result, a result at another velocity, or the result on a different model or on a hoodRequest the report itself and check the serial-number link and test conditions before treating the figure as a performance basis
General arrangement drawings, specification sheets and the English manualDimensions, flange sizes, weights and electrical supply of the offered configuration; the source text for the Turkish instructionsThat the unit fits your duct route or the hood fits your cooking line; that check belongs to your contractorSend them to whoever coordinates the ceiling void or the kitchen build-out, and to whoever prepares the Turkish instructions

This table answers what each document can carry in a submission. It does not answer what your importer or reviewer will accept; only their lists do that. Send them to us early in the enquiry and we will work out with you how to cover each item.

The certificates behind these numbers are listed by product line on our ESP certifications page. The company facts a vendor registration usually asks for are on our electrostatic precipitator supplier profile. Our units are exported to 50 countries, Turkey among them.

What to send for a quotation

“Elektrostatik filtre, fiyat?” is the enquiry that comes back with a number nobody can compare. Ten lines turn it into a quotation that can sit next to a Turkish fabricator’s offer. Three of them are there because the unit is crossing a border into a CE market: the importer and its broker, the tariff line it will declare, and who prepares the Turkish instructions. One is there because of the flue.

The 10-Input Turkey ESP Enquiry Sheet — the ten lines that make a Turkish quotation comparable with any other. The ten market-neutral inputs behind every country sheet, with where each one is found and what comes back, are set out in our electrostatic precipitator quotation guide.

#Send usWhy it matters
1Extract rate in m³/h, and who set itFixes the model size, or the number of hoods
2Cooking style and load: grill, döner, pide oven, fryers, wokSets the electrostatic tier, and whether an odor stage is worth discussing
3The space available for an in-duct unit with its access side marked, or the cooking line length for a hoodDecides the route, and within it the arrangement
4Site power supply: voltage and phase as measured at the panelTurkey is 50 Hz, as the brochure input is; the measured voltage decides which build, 220 V or 380 V, the offer names
5Whether the extract fan is in our scope, for an in-duct installationKeeps offers comparable; an HME hood carries its own fan
6Destination port and preferred Incoterm, the importer of record and its customs brokerFixes the freight basis of the proforma invoice and who the documents are issued to
7The tariff line the importer will declare, and whether its broker has checked it against the import inspection listPuts any inspection step in the schedule before the goods arrive, not at the port
8Who prepares the Turkish instructions, and the document list your consultant issuesLets us send the manual source text and assemble the pack to that list
9How the cleaned air will discharge, and whether the municipality has accepted that arrangementTells us whether the offer is for a ducted discharge as drawn, or whether a licensing question is still open
10Required on-site dateShows whether the lead time plus freight fits your schedule

What you get back:

  • The route the offer is based on, in-duct or hood, and the model selection at your airflow
  • The pressure drop of an in-duct unit stated as complete unit, or the hood’s rated airflow and electrical input
  • The model numbers checked against the CE certificate, line by line
  • A proforma invoice on your Incoterm, issued to the importer of record
  • The document list for your importer and reviewer, the manual source text, and the warranty and consumable boundary in writing

There is no list price, because the number follows the route, the airflow and the configuration. What sets an electrostatic precipitator price explains what moves it.

Scope and limits

Three layers clear separately. Layer one, the offer: the route, the configuration, the terms, the documents and the shipping record. Layer two, the site: the tariff line and any inspection, the importer’s labeling and Turkish instructions, the flue the municipality accepts, installation, ductwork, supports and access decide whether that configuration goes in as quoted. Layer three, operation: delivered airflow, capture at the hood, cleaning and consumables decide the result at the discharge. Passing one layer does not clear the next. A shipping record belongs to layer one only.

  • No prices appear on this page. Send the enquiry sheet and the price comes back against a stated configuration.
  • No transit time is stated. Ask for it with the proforma invoice and add it to the 7–15 day lead time and to any pre-permit time.
  • No Turkish project is named. Turkey is on the shipped list; that is a supply record, not a performance record.
  • The tariff reading is ours. Which GTİP line applies is decided by the importer and its broker, and the inspection route follows that line; nothing here classifies goods.
  • The flue reading is ours. This page summarizes the national texts and one municipal text; the discharge arrangement is the municipality’s decision, and nothing here is legal advice.
  • Certificates cover the models they name. The CE certificate names LK30–LK480, LK30E1–LK150E1 and the UV series; check every model number in the offer against it, ours included.
  • Nothing here is an approval. The municipality, the fire authority and the design consultant decide on the documents your contractor submits, so send us their list before the pack is assembled.
  • No cleaning interval is given. The washing interval is set in writing for your site with the configuration proposal.

Key takeaways

  • Record: Turkey is on the shipped list, but no Turkish project is published; the test report for the series offered, not the shipping record, speaks to performance.
  • Route: an elektrostatik filtre is the in-duct unit, a davlumbaz with the stage built in is the HME hood, and an odor brief points to the ecology unit configuration; match every model number against the CE certificate.
  • Import: the importer confirms the CE marking, puts its name on the equipment and supplies Turkish instructions; under GTİP 8421.39.25.90.00 a TAREKS pre-permit and a declaration approved in China come first.
  • Flue: as we read them, the national license, fire and zoning texts keep the flue; an electrostatic precipitator cleans what goes up it, and any local exception should come from the municipality in writing.
  • Enquiry: the 10-Input Turkey ESP Enquiry Sheet makes quotations comparable; “elektrostatik filtre, fiyat?” does not.

Frequently Asked Questions

Have you supplied electrostatic precipitators in Turkey?
Turkey is on the list of countries we have shipped units to, on the European line of our supplier profile, but no Turkish installation is on our published project record, and this page does not name one. The list records that units have been shipped to Turkey before; it does not show the result at your discharge, which depends on your cooking load, the delivered airflow, capture at the hood and how the cells are cleaned.
Does the unit need reconfiguring for Turkey’s 230/400 V, 50 Hz supply?
Not for the frequency. Article 7 of Turkey’s grid regulation sets the nominal system frequency at 50 Hz, which matches our brochure input: 220 V, 50 Hz for in-duct units, with 380 V three-phase configured to order, and 380 V, 50 Hz for HME hoods. State the voltage and phase measured at the panel, 230 V single-phase or 400 V three-phase; the offer names the build supplied for it, 220 V single-phase or 380 V three-phase.
Is a CE certificate enough to import a kitchen electrostatic precipitator into Turkey?
Not on its own. Our CE certificate FQC2602501 names LK30–LK480, LK30E1–LK150E1 and the UV series, and the importer confirms the CE marking and documents, puts its name on the equipment and supplies Turkish instructions. If the broker declares the unit under GTİP 8421.39.25.90.00, the 2026 machinery import communiqué adds a TAREKS pre-permit and a declaration of conformity approved by Turkey’s commercial counselor in China, with a certified Turkish translation.
Can an elektrostatik baca filtresi let a restaurant open without a flue?
Not under the national rules we read. The workplace license regulation requires a flue system in the food preparation and cooking area, the fire regulation requires restaurant kitchen exhaust to discharge directly outdoors at least 5 m from any air intake, and neither makes an exception for a filter. Gaziantep’s zoning regulation allows a flueless filtered extractor in the kitchens of independent units; ask your own municipality in writing before relying on anything similar.
How do I get a price for an electrostatic precipitator in Turkey?
Send the extract rate, the cooking style, the space or hood length, and the site supply as measured. Add whether the fan is in scope, the destination port and Incoterm, the importer of record and its broker, the tariff line it will declare, who prepares the Turkish instructions, the discharge arrangement and the on-site date. There is no list price; you get back a model selection, the CE model check and a proforma invoice to Ambarlı or Mersin.

Specifying an electrostatic precipitator for a Turkish kitchen?

Send us the extract rate, the cooking style, the space you have and the site supply as measured, and tell us who will import the units. We will come back with the route the offer is based on, a model selection and its pressure drop at your airflow, and the offered model numbers checked against the CE certificate. You also get a proforma invoice on EXW, FOB or CIF terms to Ambarlı, Mersin or the port you name, issued to your importer of record. The document list for the importer and the reviewer comes with it, along with the manual source text for the Turkish instructions.

Send your project inputs →

L
Written by Law · Project Manager, Polygee

Law manages project delivery at Polygee, from application review and equipment configuration through interfaces, installation support and handover documentation for consultants, contractors and dealers. Polygee, founded in 2004, manufactures the in-duct electrostatic precipitators and ESP hoods described here and has exported to 50 countries. This page states our published terms and shipping record; it is not a quotation, a mechanical design, a conformity declaration, a legal opinion or an approval.


References & further reading

  1. Site power, three sources — Elektrik Şebeke Yönetmeliği (EPDK; Resmî Gazete 28 May 2014, No. 29013), Article 7(1): nominal system frequency of 50 Hz, controlled by TEİAŞ between 49.8 and 50.2 Hz. Elektrik Tesislerinde Topraklamalar Yönetmeliği (Ministry of Energy and Natural Resources; Resmî Gazete 21 August 2001, No. 24500): tables worked on U0 = 230 V, 50 Hz, with 230/400 V among the installation nominal voltages. Elektrik Piyasasında Dağıtım ve Perakende Satış Faaliyetlerine İlişkin Kalite Yönetmeliği (EPDK; Resmî Gazete 29 December 2020, No. 31349), Article 25, with the EPDK Board’s procedure on the technical quality of the distribution system (Decision 9804 of 14 December 2020): TS EN 50160:2011 limits, low-voltage measurements within ±10%. mevzuat.gov.tr (grid regulation) · mevzuat.gov.tr (earthing regulation) · mevzuat.gov.tr (quality regulation)
  2. Product law — Belirli Gerilim Sınırları İçin Tasarlanan Elektrikli Ekipman ile İlgili Yönetmelik (2014/35/AB) (Resmî Gazete 2 October 2016, No. 29845), Articles 8, 10, 15 and 17; Elektromanyetik Uyumluluk Yönetmeliği (2014/30/AB), Article 11; Law No. 7223 on product safety and technical regulations (Resmî Gazete 12 March 2020, No. 31066), Article 9; European Commission, EU trade relations with Türkiye: the Customs Union covers all industrial goods and requires Turkey to align its technical legislation. mevzuat.gov.tr (LVD regulation) · mevzuat.gov.tr (EMC regulation) · mevzuat.gov.tr (Law 7223) · policy.trade.ec.europa.eu
  3. Import inspection — Ministry of Trade, TAREKS; Makinaların İthalat Denetimi Tebliği (Ürün Güvenliği ve Denetimi: 2026/32) and “CE” İşareti Taşıması Gereken Bazı Ürünlerin İthalat Denetimi Tebliği (Ürün Güvenliği ve Denetimi: 2026/9), Resmî Gazete 31 December 2025, No. 33124 (fourth repeat issue), in force 1 January 2026: in 2026/32, Annex 2/A row 10 (GTİP 8421.39.25.90.00), Article 5 (import inspection pre-permit) and Annex 3 item 3 (declaration of conformity approved by the commercial counselor in the country of departure, with a certified Turkish translation); in 2026/9, Annex 2 row 33 (household hoods up to 120 cm). Ministry of Trade customs guidance: declarations lodged by the trader or through a customs broker, whose use is not compulsory. ticaret.gov.tr (TAREKS) · mevzuat.gov.tr (2026/32) · mevzuat.gov.tr (2026/9) · ticaret.gov.tr (customs brokers)
  4. Flue and odor — İşyeri Açma ve Çalışma Ruhsatlarına İlişkin Yönetmelik (Resmî Gazete 10 August 2005, No. 25902), Annex 1, common conditions, item 6; Binaların Yangından Korunması Hakkında Yönetmelik (Resmî Gazete 19 December 2007, No. 26735), Articles 57(1) and 88(2); Planlı Alanlar İmar Yönetmeliği (Resmî Gazete 3 July 2017, No. 30113), Article 33(10); Gaziantep Büyükşehir Belediyesi İmar Yönetmeliği, Article 35(10), as amended in Resmî Gazete 2 August 2025, No. 32974; İstanbul İmar Yönetmeliği, Article 35(10); Koku Oluşturan Emisyonların Kontrolü Hakkında Yönetmelik (Resmî Gazete 19 July 2013, No. 28712), Article 2. licensing · fire protection · zoning · Gaziantep zoning · Istanbul zoning · odor regulation
  5. Ports — Marport, terminal details: a container terminal in the Ambarlı area of Istanbul, placed to serve West Marmara. PSA International, Mersin International Port terminal sheet: Türkiye’s largest and most advanced port, the primary gateway for southern Türkiye and the eastern Mediterranean, hinterland including Adana, Gaziantep, Kayseri and Konya. SOCAR Terminal, Aliağa: the largest logistics center in the Aegean. Gemport, Gemlik: describes itself as the main sea gateway for the industry of Bursa and its region. marport.com.tr · globalpsa.com (PDF) · socarterminal.com · gemport.com.tr

Related reading

  • Electrostatic precipitator Mexico — the same terms for a 60 Hz market, where the order is configured for the frequency, the importer registers in the Padrón de Importadores and Mexico City adds its environmental filing.
  • Electrostatic precipitator Australia — the same 230/400 V, 50 Hz supply, with three Sydney projects on the record and its own import rules.
  • HME ESP hood — the davlumbaz with the electrostatic stage and the fan built in: twelve models and the hood tables behind that route.
  • Kitchen ecology unit — the multi-stage train a Turkish offer means by an electrostatic filter with UV-C and carbon: eight sizes, stage tables and flange dimensions.
  • Electrostatic precipitator supplier profile — the factory, the listing, the certificates and the commercial terms behind every Polygee unit.