Electrostatic Precipitator Supply for Australian Kitchens: University of Sydney and Two More Projects on Record, Two Product Routes, and What to Send for a Quote

An electrostatic precipitator for an Australian commercial kitchen is an in-duct unit, or a hood with the cells built in, that charges grease and smoke particles and collects them on washable plates. Polygee supplies the electrostatic precipitator Australia kitchen projects fit, in both forms, from its factory in Zhangjiagang, China, with three Australian projects on record, a minimum order of one unit and a 7–15 day lead time.

This page helps you decide whether a factory-direct electrostatic precipitator suits your Australian project, whether the in-duct unit or the ESP hood is the route to price, who holds the electrical compliance once the unit lands, and what to put in the first enquiry. It does not size a unit, quote a price, register anything on the EESS database or interpret an Australian standard. For model tables, see the LK in-duct range and the HME ESP hood; for what sets the number, see what sets an electrostatic precipitator price.

QuestionOur answer
Supplied in Australia before?Yes: three projects on record. The University of Sydney in 2013 with the RY series; East Village in Zetland and the Met Centre in Sydney with in-duct units
Minimum order and lead timeOne unit; 7–15 days as standard, with freight to your port quoted with the Incoterm
Two routesAn in-duct LK or LK-E unit, from 2,000 m³/h per unit and scaled in parallel; or an HME ESP hood with the cells inside the canopy, in twelve models
Site supply230 V and 400 V standard nominal voltages at 50 Hz, as the Victorian distribution code linked below records them; the brochure input is 220 V, 50 Hz for in-duct units, with 380 V configured to order, and 380 V, 50 Hz for HME hoods
Electrical complianceThe Electrical Equipment Safety System covers household equipment and defines equipment exclusively for commercial use as not in scope; the Responsible Supplier, an Australian or New Zealand entity, decides and registers; we supply the technical file
Delivery pointCIF Port Botany or CIF Melbourne, or FOB or EXW when your forwarder books the sea leg
WarrantyOne year on the complete unit; UV lamps and carbon media, where fitted, are consumables

Three Australian projects on record, and what they do not tell you

Australia is one of our Asia Pacific export markets, and three Australian projects are on the published record. The University of Sydney was supplied in 2013 with the RY series; its unit count is given on request rather than printed here. East Village in Zetland and the Met Centre in Sydney were supplied with in-duct units on the LK or LK-E route; ask about their years and counts when you enquire. None of the three carries a performance figure, and the table says so rather than guessing.

ProjectRouteOn recordWhat it does not prove
University of SydneyRY series2013; unit count on requestThe result at your discharge; acceptance by your certifier or council
East Village, ZetlandIn-duct ESP, LK or LK-ESite supplied; series and count on requestThe same
Met Centre, SydneyIn-duct ESP, LK or LK-ESite supplied; series and count on requestThe same

This table answers what the record is. It does not answer how your installation will perform; that depends on your cooking load, the delivered airflow, capture at the hood and how the cells are cleaned, none of which a past project can settle.

Decision rule. IF you want to use this record in a vendor assessment, THEN treat it as evidence that factory-direct supply to Sydney sites has run before, BECAUSE that is the only thing a project list can prove. IF you need evidence about the result at your discharge, THEN ask for the third-party test report on the model being offered and read its test condition, BECAUSE a university kitchen in 2013 is not your kitchen.

Two product routes: in-duct unit or ESP hood

Australian enquiries split between two builds. Those asking for an electrostatic precipitator usually mean a unit in the extract duct; those asking for a hood with the filtration built in mean a canopy that carries its own cells. A third term appears on drawings: where a specification says ecology unit, it means the multi-stage version of the in-duct route, the electrostatic stage first with UV-C and activated carbon stages behind it for an odor condition, and the kitchen ecology unit page sets out that train in eight sizes. We make all of it, and the choice follows the space and the cooking line rather than a preference of ours.

RouteWhat it isBetter fit whenMain limitationWhat it means for your quote
In-duct LK or LK-E unitAn electrostatic precipitator mounted in the extract duct downstream of any hood; single units from 2,000 m³/h, scaled in parallel; the LK-E series in three tiers at or above 90, 95 and 98 percent design efficiency, 33 modelsSeveral hoods share one extract; the duct run or plant room has room; an odor stage may be added in the same run now or laterNeeds straight duct length and access on one side for washing the cellsPrice the unit and, separately, the duct adapters your contractor supplies; say whether UV-C or carbon stages are in scope
HME ESP hoodA canopy with the electrostatic cells and the fan built in; twelve models; brochure input 380 V, 50 HzA single cooking line; a fit-out where the ceiling void has no room for an in-duct unitOne hood, one line; larger extract rates mean more hoods rather than a bigger unitPrice by hood length and cooking line; the fan is inside the hood, so no separate fan line

This table answers which route to price. It does not answer the model within the route; that follows the extract rate and the cooking load, and the offer names it.

What a factory-direct order covers in Australia, and what stays with your contractor

A factory-direct order covers the equipment, the paperwork and remote support. Everything that happens on site in Australia stays with your local contractor, and two things that happen at the border stay with Australian entities: the import declaration with the importer of record, and the electrical compliance decision with the Responsible Supplier. Settle who owns each line below before comparing offers, because a line left out of one quotation does not disappear; it moves to another invoice.

ItemFactory-direct from PolygeeYour Australian contractor, importer or Responsible SupplierWhat it means for your quote
In-duct unit or ESP hood, with the high-voltage power supply and control gearSupplied, configured for the stated site supply—The part every offer should price the same way, so state the route, the airflow and the supply
UV-C or activated carbon stage, where an odor condition calls for itAvailable as modules in the same run—Say whether an odor stage is in scope; two offers with different stage lists are not comparable
Extract fanInside an HME hood; available with an in-duct unit, selected on the total static pressure of the runUsually in the mechanical services package for in-duct installationsSay which you want, or the offer that includes a fan will read as the dearer one
Ductwork, transition pieces, attenuators and any fire protection on the ductNot suppliedYesAdapter work left unstated turns into a variation after the order
Supports, hangers and structural workNot suppliedYesModule and hood weights come with the general arrangement drawings
Installation labor and commissioning attendanceNot included; paid on-site service is availableYesPrice installation locally against our drawings
Electrical compliance: the EESS scope decision, any registration and the RCMTechnical file suppliedThe Responsible Supplier, an Australian or New Zealand legal entityAgree who that is before the proforma invoice is issued
Import declaration, duty and GSTCommercial invoice, packing list and the certificate references on themThe importer of record, or its licensed customs brokerA consignment with no importer named cannot be declared
Submissions to the certifier, the council or the fire authorityDocuments prepared against the reviewer’s listThe submission itselfA late request delays approval, not delivery
Spare parts and consumablesCommon spares held in stockDecide the holding you wantQuote them with the unit, so the first order is budgeted

This table answers who supplies what. It does not answer what any of it costs; that follows the route, the airflow and the configuration.

Commercial terms, stated up front

Only the lines that change because the destination is Australia are written out here. The terms that apply to every order, payment, Incoterms, spares, remote support hours, OEM branding, the NDA and the pre-shipment inspection, are on our electrostatic precipitator supplier profile and are not restated, so you can hold any offer against them, ours included.

TermWhat applies to an Australian orderWhat it means for your project
Site supplyConfigured to the voltage and phase count measured at the panel; 50 Hz needs no changeState the measurement, not a figure copied from a standard
Delivery pointCIF Port Botany, CIF Melbourne or the port your forwarder clears at; FOB or EXW when they book the sea legName the port and the Incoterm; the proforma invoice is priced on that basis
Clearance partyThe importer of record, with its licensed customs broker, lodges the import declaration; where the equipment is in scope under the EESS, the Responsible Supplier registers it and applies the RCMBoth are Australian entities; agree who they are before the proforma invoice
Approval documentsCE and RoHS certificates for the models they name, the ISO certificates, the third-party test report for the model offered, general arrangement drawings and specification sheetsSend your reviewer’s list early; RCM evidence, where it is needed, sits with the Responsible Supplier, not in this pack
Minimum order and lead timeOne unit; 7–15 days as standardA single trial unit is a normal first order; freight time is added by route and Incoterm
WarrantyOne year on the complete unit; UV lamps and activated carbon media, where fitted, are consumables and are not coveredBudget consumables separately when an odor stage is in scope
Everything elsePayment, Incoterms, spares, remote support hours, OEM branding, NDA and factory inspectionRead them on the supplier profile; they do not change for Australia

This table answers what changes for Australia. It does not answer the price, which is set by the route, the airflow and the configuration as explained in what sets an electrostatic precipitator price.

Site power: 230/400 V, 50 Hz, and the 216–253 V band

The public instrument we can link is the Victorian one. The Essential Services Commission’s Electricity Distribution Code of Practice, version 2 of 1 May 2023, lists 230 V and 400 V among the standard nominal voltages a distributor must maintain, measured at the meter, in clause 20.4.1 and its Table 1; records in clause 20.3.1 that AEMO is responsible for system frequency and works under the National Electricity Rules to maintain it at 50 Hz; and uses 216 V and 253 V as the lower and upper bounds of its compliance test under AS 61000.3.100. Other states publish their own instruments, so whichever state your site is in, the order carries what the electrical contractor measures at the panel, not a figure copied from a code. The frequency matches our brochure input of 220 V, 50 Hz for in-duct units, with 380 V three-phase configured to order, and 380 V, 50 Hz for HME hoods, so an Australian order carries no frequency change. What it carries is the voltage and the phase count.

Site factWhere to read itWhat to state in the enquiry
FrequencyThe distributor’s connection; 50 Hz is the system frequency the Victorian code recordsNothing beyond confirming 50 Hz; no configuration change follows
Voltage and phaseThe switchboard schedule and a measurement at the panel feeding the unit230 V single-phase or 400 V three-phase, as measured; the build is configured to the stated supply
Isolator position and feeder routeThe electrical contractor’s drawingsNothing on the unit; it decides whether the access side of the run, or the hood’s service side, stays clear

This table answers what to state about the supply. It does not answer whether the feeder is adequate; that check belongs to your electrical contractor, against the electrical data on the specification sheet.

Import: the RCM question

Australian importers of electrical goods know the Regulatory Compliance Mark. The Electrical Equipment Safety System states that it is only intended to capture electrical equipment for household, personal and similar use, and that equipment exclusively for commercial or industrial use is defined as not in-scope; its risk level definition adds that it is immaterial whether equipment is marketed for commercial use as well as for household use, so a unit sold into both markets stays in scope. A commercial kitchen electrostatic precipitator is, as we read those two sentences, outside the scope. That reading is ours, not a ruling. Under the same system the decision belongs to the Responsible Supplier, which must be an Australian or New Zealand legal entity holding an Australian Business Number or a New Zealand IRD number; an overseas company cannot register, so that role sits with your importer or another Australian party, never with us. Where the Responsible Supplier finds the equipment in scope, they complete the registration its risk level requires and apply the RCM under AS/NZS 4417.1 and 4417.2. Where they find it outside the scope, the system still requires the equipment to be electrically safe against AS/NZS 3820, with the evidence held by the supplier, and notes that the Australian Communications and Media Authority may have separate requirements. In every case our part is the technical file: specification sheets, general arrangement drawings, the electrical data, and the CE and RoHS certificates for the models they name.

Two further documents are the importer’s. The Australian Border Force sets out the declarations that clear imported goods from customs control, the import declaration for sea or air cargo among them; your importer or its licensed customs broker lodges it, and duty and GST are theirs to confirm at quotation. The Department of Agriculture, Fisheries and Forestry regulates solid timber packaging on imports under ISPM 15; ask your broker what packing declaration they need and put it in the enquiry, so the packaging is confirmed at quotation rather than at the wharf.

StepWho does itWhat we supply
Name the importer of record and the Responsible SupplierYou, or your contractorThe proforma invoice, issued to the importer
Decide whether the unit is in scope under the EESSThe Responsible SupplierSpecification sheets, general arrangement drawings and the electrical data of the offered configuration
Register and mark, where in scope; hold safety evidence, where notThe Responsible SupplierCE certificate FQC2602501 for the models it names, RoHS certificate BKC25114877LC for the lines it names, the ISO certificates and the third-party test report for the model offered; anything beyond what we hold is said so in writing
Lodge the import declarationThe importer, or its licensed customs brokerCommercial invoice, packing list and the certificate references on them
Packing declaration for timber packagingThe broker asks; the packaging is confirmed at quotationThe packaging stated on the proforma invoice
Decision rule. IF no importer of record is named yet, THEN settle that before asking for a CIF price, BECAUSE the import declaration, the scope decision and the shipping documents are all issued to Australian parties. IF your contractor imports kitchen equipment regularly, THEN the enquiry only needs their name, their broker’s, and whether they will act as Responsible Supplier.

Port Botany, Port of Melbourne and the Incoterm

Sydney projects land at Port Botany, which NSW Ports describes as the largest container port in New South Wales, with three container terminals operated by DP World Australia, Patrick Terminals and Hutchison Ports. Victorian projects land at the Port of Melbourne, which describes itself as Australia’s largest capital city container and general cargo port, handling more than one-third of the nation’s container trade and serving southern New South Wales, South Australia and Tasmania as well as Victoria. A project in another state names its own port. A CIF quotation names the port as the delivery point; a FOB or EXW quotation hands the sea leg to your forwarder and the port question moves to them. Transit time is the one figure this page cannot give you. Ask for it with the proforma invoice, add it to the 7–15 day lead time, and check the total against your on-site date.

Project regionUsual gatewayWhat to write in the enquiry
Sydney and New South WalesPort Botany“CIF Port Botany”, and who clears at the port
Melbourne and Victoria; southern New South Wales, South Australia and Tasmania where your forwarder routes that wayPort of Melbourne“CIF Melbourne”, and who clears at the port
Any other stateThe port your forwarder clears at“CIF” with that port named, and who clears there
Anywhere, when your forwarder books the sea legThe Chinese load port named on the proforma invoice“FOB” or “EXW”, with your forwarder’s details

This table answers which port to name. It does not answer the transit time or the clearance cost at the port; both come from your forwarder and broker.

Documents for the consultant or the authority

We prepare the submission pack against the list your reviewer issues: certificates, third-party test reports, general arrangement drawings and specification sheets, put together for the market you are submitting in. The approvals themselves stay with your contractor: the certifier, the council and the fire authority review the installation through the project’s own submission, and nothing in the pack is an approval or an RCM registration.

DocumentWhat it supportsWhat it does not prove on its ownWhat to check
CE certificate FQC2602501 (Machinery, EMC and Low Voltage directives)Conformity of the models it names: the LK series LK30–LK480, the LK-E series and the UV seriesCoverage of any model not named on it, the HME hoods included; acceptance by an Australian regulator, which the CE marking does not addressMatch the model numbers in the offer against the certificate
RoHS 2.0 certificate BKC25114877LCRestricted-substance compliance for the lines it names, the LK, LK-E and HME series among themCoverage beyond the lines it names; electrical safety of any kindThe same model-number check
ISO 9001, ISO 14001 and ISO 45001 certificates (ABZB25Q30072R3M, ABZB25E30043R3M, ABZB25S30027R2M)The management systems the factory works underThe performance of any particular unitAsk for copies with the pack
Third-party test report ZY05W230298 (CMA-accredited)Grease removal of up to 97.6% on LK units at rated, evenly distributed airflow, under that testAn odor result, a result at another velocity, or the result on a different model or on a hoodRequest the report itself and check the serial-number link and test conditions before treating the figure as a performance basis
General arrangement drawings and specification sheetsDimensions, flange sizes, weights and electrical supply of the offered configuration, hood or in-ductThat the unit fits your duct route or the hood fits your cooking line; that check belongs to your contractorSend them to whoever coordinates the ceiling void or the kitchen fit-out

This table answers what each document can carry in a submission. It does not answer what your reviewer will accept; only their list does that. Send it to us early in the enquiry and we will work out with you how to cover each item.

The certificates behind these numbers are listed by product line on our ESP certifications page. The company facts a vendor registration usually asks for are on our electrostatic precipitator supplier profile. Our units are exported to 50 countries, Australia among them.

What to send for a quotation

An enquiry that says “ESP, send price” gets back a number that cannot be compared with anything. The sheet below is what turns it into a quotation you can line up against other offers, including a local supplier’s. It carries two lines a domestic enquiry does not: the importer of record, and who will act as Responsible Supplier.

The 9-Input Australia ESP Enquiry Sheet — the nine lines that make an Australian quotation comparable with any other. The ten market-neutral inputs behind every country sheet, with where each one is found and what comes back, are set out in our electrostatic precipitator quotation guide.

#Send usWhy it matters
1Extract rate in m³/h or L/s, and who set itFixes the model size, or the number of hoods
2Cooking style and loadSets the electrostatic tier, and whether an odor stage is worth discussing
3The space available for an in-duct unit with its access side marked, or the cooking line length for a hoodDecides the route, and within it the arrangement
4Site power supply: voltage and phase, as measured at the panelAustralia is 50 Hz, as the brochure input is; 230 V single-phase or 400 V three-phase as measured sets the build
5Whether the extract fan is in our scope, for an in-duct installationKeeps offers comparable; an HME hood carries its own fan
6Delivery point and preferred Incoterm, the importer of record, and who will act as Responsible SupplierFixes the freight basis of the proforma invoice, who the documents are issued to, and who takes the EESS scope decision
7Who reviews the submission, and the document list they issueLets us assemble the pack to that list
8Required on-site dateShows whether the lead time plus freight fits your schedule
9Whether you want the Australian project record set out in the offerPuts the record in writing next to the configuration it is being compared with

What you get back:

  • The route the offer is based on, in-duct or hood, and the model selection at your airflow
  • The pressure drop of an in-duct unit stated as complete unit, or the hood’s own fan data
  • A proforma invoice on your Incoterm, issued to the importer of record
  • The technical file list for the Responsible Supplier, and the submission pack list matched to your reviewer
  • The warranty and consumable boundary, in writing

There is no list price, because the number follows the route, the airflow and the configuration. What sets an electrostatic precipitator price explains what moves it.

Scope and limits

Three layers clear separately. Layer one, the offer: the route, the configuration, the terms, the documents and the project record. Layer two, the site: the EESS scope decision, the import declaration, installation, ductwork, supports and access decide whether that configuration goes in as quoted. Layer three, operation: delivered airflow, capture at the hood, cleaning and consumables decide the result at the discharge. Passing one layer does not clear the next. A past project belongs to layer one only.

  • No prices appear on this page. Send the enquiry sheet and the price comes back against a stated configuration.
  • No transit time is stated. Ask for it with the proforma invoice and add it to the 7–15 day lead time.
  • The project list is a supply record. One of the three entries carries a year and a series on this page, none carries a unit count, and none carries a performance figure.
  • The EESS reading is ours. Whether a unit is in scope is decided by the Responsible Supplier, an Australian or New Zealand entity, not by this page; we do not register, and nothing here says a unit is registered or carries the RCM.
  • No Australian standard is interpreted here. Where your specification cites one, your consultant reads it; we supply the data the reading needs.
  • Certificates cover the models they name. The CE certificate does not name the HME hoods; check the model numbers on each certificate against the offer, ours included.
  • Nothing here is an approval. The certifier, the council and the fire authority decide on the documents your contractor submits, so send us their list before the pack is assembled.
  • No cleaning interval is given. The washing interval is set in writing for your site with the configuration proposal.

Key takeaways

  • Record: three Australian projects show that supply has run before; the test report, not the project list, speaks to performance.
  • Route: several hoods on one extract point to an in-duct unit; a single line with no duct space points to an ESP hood; an odor condition points to the ecology unit configuration of the in-duct route.
  • Supply: Australia is 50 Hz like the brochure input, so state the voltage and phase as measured, 230 V or 400 V.
  • Compliance: the EESS is written for household equipment; the Responsible Supplier, an Australian or New Zealand entity, decides the scope, and we supply the file.
  • Enquiry: the 9-Input Australia ESP Enquiry Sheet makes quotations comparable; “send price” does not.

Frequently Asked Questions

Have you supplied electrostatic precipitators in Australia?
Yes. Three Australian projects are on record. The University of Sydney was supplied in 2013 with the RY series, and East Village in Zetland and the Met Centre in Sydney were supplied with in-duct units on the LK or LK-E route. Ask about unit counts, and the years of the two Sydney sites, when you enquire. The record shows that factory-direct supply to Sydney sites has run before; it does not show the result at your discharge.
Does the unit need reconfiguring for Australia’s 230/400 V, 50 Hz supply?
Not for the frequency. The Victorian distribution code we link lists 230 V and 400 V as standard nominal voltages at the meter, records 50 Hz as the system frequency and uses 216 V to 253 V as its compliance band. The brochure input is 220 V, 50 Hz for in-duct units, with 380 V three-phase configured to order, and 380 V, 50 Hz for HME hoods. Write down the voltage and phase measured at the panel, and the order is configured to that.
Does a commercial kitchen electrostatic precipitator need the RCM in Australia?
As we read the Electrical Equipment Safety System, no: it defines in-scope equipment as equipment for household, personal or similar use, and equipment exclusively for commercial or industrial use as not in-scope. That reading is not a ruling. The Responsible Supplier, an Australian or New Zealand legal entity, decides it, because an overseas company cannot register on the EESS database. Our part is the technical file. Not-in-scope equipment must still be electrically safe, and ACMA rules may apply separately.
Is an ecology unit the same as an electrostatic precipitator?
No. An electrostatic precipitator is one stage; an ecology unit is a train of stages in one duct run, the electrostatic stage first, then UV-C for odor molecules and activated carbon for what is left. Where an Australian drawing says ecology unit, price the in-duct route with the odor stages added; where it says ESP or precipitator, price the single stage. The kitchen ecology unit page sets out the eight sizes from 3,000 to 15,000 m³/h.
How do I get a price for an electrostatic precipitator in Australia?
Send the extract rate, the cooking style, the space or hood length, and the site supply as measured. Add whether the fan is in scope, the delivery point and Incoterm, the importer of record, the reviewer’s document list and the required on-site date. There is no list price, because the airflow and the configuration decide most of the number. You get back a model selection, a proforma invoice on your Incoterm and the document list for your reviewer.

Specifying an electrostatic precipitator for an Australian kitchen?

Send us the extract rate, the cooking style, the space you have and the site supply as measured. We will come back with the route the offer is based on, a model selection and its pressure drop at your airflow, a proforma invoice on EXW, FOB or CIF terms to Port Botany, Melbourne or the port you name, issued to your importer of record, the technical file list for your Responsible Supplier, and the list of documents we will prepare for your reviewer. Ask for the Australian project record and it goes in the same offer.

Send your project inputs →

S
Written by Scarlett · Business Director, Polygee

Scarlett handles export inquiries, dealer relationships and commercial terms at Polygee, including institutional, mall and restaurant kitchen projects across Asia Pacific and the Gulf. Polygee, founded in 2004, manufactures the in-duct electrostatic precipitators and ESP hoods described here and has exported to 50 countries. This page states our published terms and project record; it is not a quotation, a mechanical design, a compliance declaration or an approval.


References & further reading

  1. Essential Services Commission (Victoria) — Electricity Distribution Code of Practice, Version 2, 1 May 2023: clause 20.3.1 on AEMO working under the National Electricity Rules to maintain system frequency at 50 Hz; clause 20.4.1 and Table 1 on the 230 V and 400 V standard nominal voltages measured at the meter; the AS 61000.3.100 compliance band of 216 V to 253 V. esc.vic.gov.au (PDF)
  2. Electrical Equipment Safety System (EESS) — Not in-scope electrical equipment: household, personal and similar use as the scope; equipment exclusively for commercial or industrial use defined as not in-scope; AS/NZS 3820 for equipment outside the scope; the ACMA note. Risk level definition: it is immaterial whether equipment is also marketed for commercial use. Manufacturers and importers as Responsible Suppliers: an Australian or New Zealand legal entity holding an ABN or a New Zealand IRD number; an overseas company cannot register. RCM: marking under AS/NZS 4417.1 and 4417.2. eess.gov.au (scope) · eess.gov.au (risk levels) · eess.gov.au (RCM) · eess.gov.au (Responsible Supplier)
  3. NSW Ports — Port Botany: the largest container port in New South Wales, with three container terminals operated by DP World Australia, Patrick Terminals and Hutchison Ports. nswports.com.au