Polygee Kitchen Ecology Unit — LK-E, UV-C and CB Modules in One Duct Run

The Polygee kitchen ecology unit is a three-stage exhaust treatment train built from our own modules: an LK-E electrostatic stage, a dual-band UV-C stage and a CB activated carbon stage, configured to your airflow — with the matched extract fan supplied too, if you want it quoted that way. It removes grease, smoke and odor in sequence rather than one stage at a time.

3 Stages
ESP · UV-C · Carbon
3,000–15,000
m³/h Per Treatment Run
1 Unit
Minimum Order Quantity
7–15 Days
Standard Lead Time

Kitchen Ecology Unit for Commercial Kitchen Exhaust

An ecology unit is a multi-stage kitchen exhaust treatment train rather than a single device. The Polygee configuration puts an LK-E electrostatic stage first for grease and smoke, a dual-band UV-C stage second for odor molecules, and a CB activated carbon stage last for the residual VOCs. The stages ship as modules on a common flange height and are bolted into one continuous run, or stacked, according to the plant room you have. The matched extract fan can be supplied with them on request.

ESP + UV-C + CarbonThree Treatment Stages
3,000–15,000 m³/hPer Treatment Run
220V / 380V · 50/60HzConfigured to Order
1 YearWarranty, Complete Unit
Get an Ecology Unit Quote →
Kitchen ecology unit — ESP with UV-C and activated carbon odor control combination for kitchen exhaust
Product Gallery

The Three Stages Inside a Polygee Ecology Unit

Terminology

Ecology Unit, ECU or Pollution Control Unit for Kitchen Exhaust — Same Equipment, Different Markets

The same equipment goes by different names depending on which market the tender was written in. Getting the naming straight avoids quoting the wrong scope. Four companion guides sit behind this page: what an ecology unit is, stage by stage, and what the straight run, weight, pressure allowance and access clearance have to be before a three-stage train will physically go in, in ecology unit installation. The recurring side — which stage is washed and which are consumed — is in ecology unit filters, and what moves the capital number is in ecology unit price.

What a kitchen ecology unit is

An ecology unit is a packaged multi-stage treatment train for commercial kitchen exhaust. It is defined by the sequence of stages it contains, not by a single technology. A typical train removes particles first, treats odor molecules second, and adsorbs what is left third, so that the air reaching the discharge point has been through more than one mechanism.

What a kitchen ecology unit is called in other markets

Gulf tenders and UK ventilation specifications tend to say ecology unit or ECU. North American drawings for the same duty usually say pollution control unit, abbreviated PCU — a term used both for a single in-duct ESP and for a full multi-stage train, so check the stages listed on the drawing. Indian enquiries often say kitchen exhaust scrubber, even where no water is involved. If your document uses one of those terms, the scope described on this page is the one being asked for.

What a kitchen ecology unit is not

  • Not a baffle or mesh grease filter — those sit inside the hood and stop bulk grease, upstream of everything here
  • Not a wet scrubber — the Polygee train is dry, with no water supply, no drain and no chemical dosing
  • Not a stand-alone electrostatic precipitator — the LK-E series and the LK in-duct range are the first stage of the train, not the whole train
  • Not a stand-alone UV module or carbon box — each is one stage, sold separately for buyers who already own the others
  • Not an ESP hood — that is a hood with a built-in cell, mounted over the cooking line rather than in the duct run
  • Not a fan set on its own — the extract fan can be supplied with the train when you want it quoted that way, but on most projects it sits in the ventilation contractor package
Ecology unit configuration diagram showing single-run, stacked and ESP plus UV plus carbon arrangements

The same modules arranged as one straight run or stacked in layers — the layout is set on the project drawing.

Product Advantages

8 Reasons Buyers Specify a Polygee Ecology Unit

Every stage in the train is a Polygee product with its own brochure specification, so the configuration can be checked module by module before you order.

🔗

One Supplier for All Three Stages

ESP, UV-C and carbon come from the same factory and are set out on one project drawing, so there is no interface argument between three vendors when something needs sorting.

⚡

ESP Tier Chosen for the Load

LK-E0, LK-E1 and LK-E2 give ≥ 90%, ≥ 95% and ≥ 98% design efficiency. A bakery and a charcoal grill do not need the same first stage.

💧

Dry Process, No Water Services

No water supply, no drain, no chemical dosing and no effluent to handle — the whole train runs dry, which is what keeps it viable in a rooftop plant room.

🧼

Washable First Stage

The electrostatic cells are stainless steel and are washed and refitted rather than thrown away. Only the UV lamps and the carbon media are consumables.

📐

Matched Module Geometry

UV and carbon stages share a common 653 mm flange height, with matched widths at most sizes, so the modules line up in a straight run. At 12,000 m³/h the UV and carbon flanges differ by 50 mm and are joined with a transition piece.

🗄

Serviceable From the Front

Drawer-type cells, lamp racks and carbon panels, with D = 1,000 mm maintenance clearance on the access side of the UV and carbon stages.

🧱

Stacked or In-Line

The same modules can be arranged as one straight run or stacked in layers when the plant room is short of length. The layout is set on the project drawing.

⚙

OEM / ODM Builds

Your logo on the unit and a different enclosure color are available, and integrated ODM ecology units have been supplied on a project basis.

Working Principle

How a Kitchen Ecology Unit Works — 3 Treatment Stages, Plus the Hood Filters Upstream

Each stage removes what the stage before it cannot, and each one protects the stage after it.

Kitchen ecology unit working principle — ESP, UV-C and activated carbon stages in sequence
Stage 0

Hood Filters

Baffle or mesh filters in the hood take out bulk grease. They belong to the hood, not to the ecology unit, but the train depends on them working.

→
Stage 1

Electrostatic Precipitation

The LK-E cell charges the grease and smoke particles and collects them on stainless-steel plates. This is the stage that stops the duct downstream from coating up — the mechanism is explained in what an electrostatic precipitator is.

→
Stage 2

UV-C Photolysis

The 254 nm band breaks odor molecules apart; the 185 nm band splits oxygen so that ozone forms inside the chamber and oxidises the fragments.

→
Stage 3

Carbon Adsorption

The CB carbon panels adsorb the residual VOCs that survive photolysis. This is the last stage before the fan and the terminal.

Route Comparison

Ecology Unit vs. Single-Stage ESP vs. Wet Process vs. ESP Hood

Four routes get specified for the same duty. They differ in what they remove, what they consume, and who maintains them.

✅ Ecology Unit (ESP + UV-C + Carbon)

Removes particles, treats odor molecules and adsorbs residual VOCs in one train. The route to specify when there is an odor condition attached to the discharge point. The longest module run of the four, so the plant room has to take it and the total static pressure has to be added up stage by stage before the fan is selected.

⚡ Single-Stage ESP Only

Removes grease and smoke particles and keeps the duct clean, which is often all a landlord condition or a local requirement is asking for. It does not treat gaseous odor at all, so it is the wrong route where neighbors or a landlord have raised smell rather than smoke. See the in-duct electrostatic precipitator for that route.

💧 Wet Scrubber

Uses a water circuit to wash the airstream. It needs a water supply, a drain, effluent handling and freeze protection, and adds humidity to the discharge. The Polygee ecology unit is a dry alternative for projects where those services are difficult to provide.

🏠 ESP Hood (Hood-Integrated)

Puts the cell inside the hood over the cooking line, which suits new-build kitchens with no plant room for a duct-mounted train. Treatment is a single stage, and the airflow band is narrower. See the commercial kitchen hood system for that route.

RouteRemoves ParticlesTreats Gaseous OdorWater ServicesWhere It SitsTypical Trigger
Ecology unit (ESP + UV-C + carbon)YesYes, two stagesNoneDuct run or plant roomOdor condition on the discharge point
Single-stage ESPYesNoNoneIn-ductGrease and smoke only
Wet scrubberYesPartlySupply, drain, effluentPlant roomSpecification calls for a wet process
ESP hoodYesNoNoneOver the cooking lineNew build with no plant room
System Integration

Recommended Layout for a Kitchen Ecology Unit

The order of the stages is not interchangeable. Each one is sized on the assumption that the stage in front of it is doing its job.

Stage 1

LK-E Electrostatic Stage

Grease and smoke particles are charged and collected here. Put anything else first and the UV lamps and carbon media foul early, which is the single most common reason an ecology unit underperforms in service.

  • Three tiers: ≥ 90%, ≥ 95% and ≥ 98% design efficiency
  • Washable stainless-steel collecting cells, no filter media to buy
  • Complete module rated at no more than 150 Pa with its airflow distribution plate; the electrostatic field itself contributes 20–30 Pa (brochure equipment resistance 31 Pa on E0, 23 Pa on E1, 34 Pa on E2)
Stage 2

UV-C Photolysis Stage

Dual-band lamps attack the odor molecules the ESP cannot capture, because odor is a gas and the electrostatic stage only works on particles. The ozone generated at 185 nm is consumed inside the duct run, provided the section downstream of the lamp rack is dimensioned for the required dwell time, which is set case by case on the project drawing.

  • Eight models, UV30 to UV150, 3,000 to 15,000 m³/h
  • 220V/50Hz standard, aluminum profile lamp frame, safety interlock
  • Lamps are consumables; the replacement schedule comes with the proposal
  • Stage resistance is issued per model with the configuration proposal — it is the one figure not published in the brochure
Stage 3

CB Activated Carbon Stage

The last stage adsorbs residual VOCs before the fan. Because the two stages upstream have already taken out the particles and much of the odor load, the carbon is not asked to do the whole job on its own.

  • Eight models, CB30 to CB150, 3,000 to 15,000 m³/h
  • Coal-based columnar carbon, iodine adsorption value ≥ 800 mg/g
  • Equipment resistance stated per model with the quotation — include it in the fan calculation
Recommended sequence: hood with baffle filters → LK-E electrostatic stage → UV-C photolysis stage → CB activated carbon stage → extract fan → discharge terminal. The fan sits downstream of the treatment train so the modules run under negative pressure. Total static pressure has to be added up across the whole run before the fan is selected, using the complete-module figures rather than the cell-only figures: no more than 150 Pa for the LK-E stage with its airflow distribution plate, and the carbon-stage figure stated for the CB model and airflow in your quotation. On the UV stage, a third-party report on UV80 at 8,030 m³/h measured 65 Pa (report 2018I20-35-1594159016); the brochure does not publish a UV figure for the other sizes, so ask us for the one that applies to your model.
Configuration

Kitchen Ecology Unit — Configuration and Stage Specifications

Start from the extract rate. That fixes the UV and carbon module sizes; the ESP tier is then chosen from the cooking load.

📋 Brochure data for the Polygee modules that make up the train. One treatment run covers 3,000 to 15,000 m³/h, which is the band where the UV and carbon modules exist; above that the extract is split into parallel runs, confirmed on the project drawing. 1 m³/h ≈ 0.5886 CFM (3,000 ≈ 1,766 CFM; 15,000 ≈ 8,830 CFM). LK-E0 starts at 4,000 m³/h, so the 3,000 size uses LK-E1 or LK-E2. Brochure input supply is 220V/50Hz across the LK-E and UV modules; 380V and 60Hz are configured to order. Maintenance clearance D = 1,000 mm on the access side of the UV and carbon stages. Warranty: 1 year on the complete unit; UV lamps and activated carbon media are consumables and are excluded • MOQ: 1 unit • Lead time: 7–15 days • Support: Mon–Fri 8:00–17:00 (GMT+8).
Nominal Airflow (m³/h)≈ CFMESP StageUV StageCarbon StageUV Flange A×B (mm)Carbon Flange A×B (mm)Carbon Frames (pcs)
3,0001,766LK-E1 / LK-E2UV30CB30470×653470×6534
4,0002,354LK-E tier to suitUV40CB40638×653638×6534
5,0002,943LK-E tier to suitUV50CB50690×653690×6534
6,0003,532LK-E tier to suitUV60CB60980×653980×6538
8,0004,709LK-E tier to suitUV80CB801316×6531316×6538
10,0005,887LK-E tier to suitUV100CB1001420×6531420×6538
12,0007,064LK-E tier to suitUV120CB1201944×6531994×65312
15,0008,830LK-E tier to suitUV150CB1502150×6532150×65312
ESP TierModelsAirflow Range (m³/h)Design EfficiencyEquipment Resistance (Pa)Input SupplyTypical Use in an Ecology Unit
LK-E211 (LK30E2–LK240E2)3,000–24,000≥ 98%34220V/50HzCharcoal, grill and heavy wok lines; tight landlord conditions
LK-E111 (LK30E1–LK240E1)3,000–24,000≥ 95%23220V/50HzGeneral restaurant and hotel kitchens; the usual starting point
LK-E011 (LK40E0–LK400E0)4,000–40,000≥ 90%31220V/50HzLighter loads, and large extract rates handled in parallel runs
Carbon Media ParameterSpecificationCarbon Media ParameterSpecification
Iodine adsorption value≥ 800 mg/gCarbon tetrachloride adsorption≥ 45%
Methylene blue adsorption≥ 100 mg/gBenzene adsorption≥ 40%
Specific surface area≥ 800 m²/gStrength≥ 95%
Packing density650 ± 50 g/LMoisture≤ 10%
Ash≤ 15%Heavy metal (as iron)≤ 3%

Full per-model tables live on the stage pages: LK-E series, UV odor control and activated carbon filter. Brochure dimensions can be customized for project-specific duct layouts. Datasheets, certificates and drawings are emailed on request from the downloads center.

Send the extract rate, the cooking style and the plant room dimensions and we will come back with a stage-by-stage configuration and a quotation.

Request an Ecology Unit Configuration →
🧭 Selecting an Ecology Unit — What Actually Decides It

Comparing suppliers as well as sizes? The commercial kitchen ESP buying guide sets out what to ask each of them for.

  • Extract rate fixes the module size — the UV and carbon stages exist in eight sizes from 3,000 to 15,000 m³/h
  • Cooking style fixes the ESP tier — charcoal and wok lines sit at the ≥ 98% end, cafés at the ≥ 90% end
  • Static pressure is added across all three complete modules plus the ductwork — use the module figures, not the cell-only figures
  • Plant room length decides whether the train runs straight or is stacked in layers
  • If the kitchen runs demand-control ventilation, size the train for the highest airflow the fan will deliver rather than the average — see demand control kitchen ventilation
  • Whatever extract rate you settle on has to be replaced by the same volume of air coming in — see commercial kitchen makeup air requirements
  • Above 15,000 m³/h the extract is split into parallel runs; the split is set on the project drawing
  • Leave D = 1,000 mm clear on the access side of the UV and carbon stages or the unit cannot be serviced
Certification & Documents

Certification and Submission Documents for an Ecology Unit

Certificate numbers, directives and covered series — stated so your consultant can check them, and packaged so they can be filed with a local submission.

✅ CE — Certificate FQC2602501

Valid to 9 January 2031 and naming the LK series (LK30–LK480), the LK-E1 range LK30E1–LK150E1 and the UV series against three directives: Machinery 2006/42/EC, EMC and LVD. We confirm in writing which certificate applies to the exact models in your configuration before you submit. Machinery-directive coverage on a kitchen-exhaust product line is not common, and this is the certificate that goes into the submission for the electrostatic and UV stages. The LK-E stage is additionally covered by RoHS certificate BKC25114877LC.

🏭 ISO 9001 / 14001 / 45001

Manufacturing runs under three certified management systems: ISO 9001 ABZB25Q30072R3M, ISO 14001 ABZB25E30043R3M and ISO 45001 ABZB25S30027R2M. The activated carbon stage is a passive component with no electrical parts, so it is built and inspected under this scope.

📄 What We Send for a Submission

Certificates, third-party test reports, general arrangement drawings and specification sheets, put together for the market you are submitting in. We have supplied projects in Dubai and across the Gulf — among them Dubai Mall in 2017, 40 ODM units — so we know the form a submission usually takes there. Tell us the authority or the consultant reviewing it and we assemble the pack to match, at no charge.

🔎 Checkable, Not Decorative

Every certificate here is quoted with its number, its scope and its expiry, so it can be verified before you commit. Ask for the originals and we send the scans. Scope by product line across the whole Polygee range is set out on the ESP certifications page.

💬 What Consultants Actually Ask Us — From the Project Team

“The first question I get from a consultant is never about efficiency, it is which certificate covers which part of the train, and can they file it. So we put the number, the directive and the covered series on the page instead of a row of logos, and we send the same documents in a pack they can hand straight to the authority. If your reviewer asks for something specific, tell us early in the enquiry and we will work out how to cover it with you.”
— Law, Project Manager, Jiangsu Polygee Environmental Technology Co., Ltd.

Ordering & Support

Ordering, Warranty and After-Sales Terms for an Ecology Unit

The commercial baseline for ecology unit orders. Every point below is restated in writing on your quotation and pro forma invoice.

Payment

Deposit and Balance

A 30% deposit releases production, with the balance settled before shipment. A 50% deposit is also available if your procurement rules ask for it.

  • T/T and L/C are both accepted
  • Balance due before the goods leave the factory
  • Bank details stated on the pro forma invoice
Trade Terms

Incoterms to Suit the Buyer

Incoterms arranged to suit the buyer (EXW / FOB / CIF). Tell us the delivery point and we quote on that basis.

  • EXW for buyers using their own forwarder
  • FOB from a Chinese port of loading
  • CIF to your named port of destination
Warranty

1 Year on the Complete Unit

Each module carries a 1-year warranty on the complete unit. The electrostatic cells and the SPP high-voltage power supplies are covered.

  • UV lamps and activated carbon media are consumables and are excluded
  • Labor and site attendance not included; paid on-site service available
  • Spare parts supplied for 1 year after a model is discontinued
MOQ

One Unit, 7–15 Days

MOQ is 1 unit and standard lead time is 7–15 days. Project and volume pricing is quoted per project.

  • Single-unit and sample orders accepted
  • Individual stages can be ordered separately for a staged upgrade
  • OEM minimum order quantity and lead time agreed case by case
Scope of Supply

Treatment Stages, With or Without the Fan

The standard scope is the treatment modules with their control gear. We can also supply the matched extract fan with the train, so the airflow and the treatment come from one supplier and one party is answerable for the duty point. Say which you want on the enquiry.

  • Fan supplied and matched to the total static pressure of your configuration, on request
  • Flange sizes and transition pieces confirmed against your duct
  • Attenuator, fire damper and ductwork remain with the ventilation contractor
After-Sales

Remote Support and OEM

Remote support runs on video calls backed by illustrated manuals, Mon–Fri 8:00–17:00 (GMT+8). Paid on-site service is available.

  • Your logo on the unit and a different enclosure color are available
  • NDA signed by the company on request
  • Manufacturing under ISO 9001 / 14001 / 45001 management systems
Engineering Support

Drawings and Specifications

Stage-by-stage configuration proposals, CAD drawings and full specification sheets — request them with your project’s extract rate and plant room dimensions.

Polygee is a Beijing Stock Exchange listed manufacturer (code 920802), founded in 2004, with 225 patents granted (cumulative), including 39 invention patents, and equipment exported to 50 countries — more about the factory. Reselling or fitting ecology units in your market? Terms for partners are on the distributor programme page, and general enquiries go through contact us.
Installation Guide

4 Ways to Install an Ecology Unit in a Kitchen Exhaust System

The stages bolt together on a common flange height, so an ecology unit kitchen layout follows the space rather than the other way round — whether the drawing came from a Gulf consultant, a UK ventilation specification or a North American PCU schedule.

🔗 Straight In-Line Run

ESP, then UV, then carbon in one continuous horizontal run in the duct. The simplest arrangement to service and the easiest to commission, and the default where the plant room has the length for it.

🧱 Stacked Layout

Where length is short, the modules are stacked in layers with transition sections between them. This is the arrangement shown in the modular combination diagram and is common in retail units and basement plant rooms.

🏗 Rooftop Plant Room

The whole train installed at roof level ahead of the discharge terminal. Outdoor and rooftop enclosure options are available on request. Keep the maintenance access clear on the UV and carbon stages.

⚙ Staged Retrofit

Add stages to an existing system over time — typically a UV and carbon stage behind an ESP that is already installed, including a third-party one. Standard flange sizes with transition pieces available.

📐 Installation & Maintenance Notes
  • Keep the stage order — ESP first, then UV, then carbon; reordering it shortens the life of the consumables
  • Allow D = 1,000 mm maintenance clearance on the access side of the UV and carbon stages
  • Site the extract fan downstream of the train so the modules run under negative pressure
  • Add up the complete-module static pressure of every stage plus the ductwork before the fan is selected
  • Wire the UV safety interlock to the fan system, and provide access doors at each stage
  • Electrostatic cells are washed and refitted; UV lamps and carbon panels are replaced on schedule
  • Isolate the power supply and allow the high-voltage section to discharge before any cell is removed; change UV lamps with the interlock proved and the lamps de-energized. All service by competent personnel, per the manual

💬 Sizing an Ecology Unit — From the Project Team

“The first question I ask is not which model, it is what the extract rate is and what is being cooked under the hood. The airflow fixes the UV and carbon module size straight away, because those exist in eight sizes and nothing else. The cooking decides the ESP tier, and that is where buyers most often over-specify or under-specify. The third question is the plant room, because a train that will not fit has to be stacked, and that changes the drawing. Give me those three answers and the configuration comes back within 24 hours on business days.”
— Scarlett, Business Director, Jiangsu Polygee Environmental Technology Co., Ltd.

FAQ

Frequently Asked Questions About Kitchen Ecology Units

What buyers and consultants ask before specifying an ecology unit. Site-wide answers are collected on the Polygee kitchen ESP FAQ.

What is a kitchen ecology unit?

▼
A kitchen ecology unit is a multi-stage treatment train fitted in a commercial kitchen exhaust duct. It is defined by the sequence of stages inside it rather than by one technology. A Polygee ecology unit puts an LK-E electrostatic stage first to remove grease and smoke particles, a dual-band UV-C stage second to break down odor molecules, and a CB activated carbon stage third to adsorb the residual VOCs before the air reaches the extract fan and the discharge terminal.

What is the difference between an ecology unit and an electrostatic precipitator?

▼
An electrostatic precipitator is one stage; an ecology unit is the whole train. The ESP charges and collects grease and smoke particles, which keeps the duct clean and handles the visible part of the problem. It does not treat gaseous odor, because odor molecules are not particles. An ecology unit adds a UV-C stage and an activated carbon stage behind the ESP for exactly that reason. If the complaint is smoke, an ESP on its own may be enough; if the complaint is smell, the additional stages are what address it.

Is an ecology unit the same as a pollution control unit or an ECU?

▼
In most enquiries, yes — the names differ by market. Gulf and UK specifications say ecology unit or ECU. North American drawings for the same duty usually say pollution control unit, or PCU, a term used both for a single in-duct ESP and for a full multi-stage train, so check the stages listed on the drawing. Indian enquiries often say kitchen exhaust scrubber even where no water is involved. One caution on that last term: a true wet scrubber uses a water circuit and needs a supply, a drain and effluent handling. The Polygee train is dry throughout, with no water and no chemical dosing, so if your specification calls for a genuine wet process this is not that product.

Does a Polygee ecology unit include the extract fan?

▼
Not as standard, but yes, we can supply it. The default scope is the treatment stages with their control gear, because on most projects the extract fan already sits in the ventilation contractor package. If you would rather buy the fan with the unit, say so on the enquiry and we quote a fan matched to the total static pressure of your configuration, so one supplier is answerable for the duty point. Either way you get the resistance figures the fan selection needs: the LK-E stage is rated at no more than 150 Pa complete with its airflow distribution plate, of which the electrostatic field itself contributes 20 to 30 Pa, and the carbon-stage figure is stated for the CB model and airflow in your quotation.

How much does a kitchen ecology unit cost?

▼
Price is driven by the extract rate, which fixes the module sizes, and by the ESP tier, which is chosen from the cooking load. A three-stage train at 3,000 m³/h and a three-stage train at 15,000 m³/h are different pieces of equipment. Because of that we quote per configuration rather than publishing a list price. Minimum order quantity is 1 unit and standard lead time is 7 to 15 days, and Incoterms are arranged to suit the buyer, so an EXW figure and a CIF figure to your port will not be the same number. Send the extract rate, the cooking style and the plant room dimensions and you get a stage-by-stage quotation back.

What maintenance does an ecology unit need?

▼
Three different routines, one per stage. The electrostatic cells are washable stainless steel: they are removed, washed and refitted, with no media to buy. Isolate the power supply and let the high-voltage section discharge before any cell comes out, and have the work done by competent personnel. The UV lamps are consumable items and are changed on a schedule supplied with the system proposal. The activated carbon panels are also consumables: the optional differential pressure gauge on the carbon stage flags dust loading and airflow loss across the panels, but adsorption capacity itself does not show on a gauge, so the carbon is replaced on the schedule in the proposal and brought forward if odor returns at the terminal. Allow D = 1,000 mm clearance on the access side of the UV and carbon stages so all three routines can actually be carried out.

What certification does the ecology unit carry?

▼
The stages are certified individually, and the certificate that goes into a submission for the electrostatic and UV stages is CE FQC2602501, valid to 9 January 2031, naming the LK series (LK30 to LK480), the LK-E1 range LK30E1 to LK150E1 and the UV series against the Machinery, EMC and LVD directives. The LK-E stage is also covered by RoHS certificate BKC25114877LC. We confirm in writing which certificate applies to the exact models in your configuration before you submit. The activated carbon stage is a passive component with no electrical parts, so it is built and inspected under the company management systems: ISO 9001, ISO 14001 and ISO 45001, with the certificate numbers listed above. For a local approval submission we assemble the certificates, third-party test reports and general arrangement drawings for the market you are submitting in, at no charge. Tell us the authority or the consultant reviewing it and we put the pack together.

Can an ecology unit be retrofitted to an existing kitchen exhaust system?

▼
Yes, and it is a common way to buy one. The usual retrofit adds a UV stage and a carbon stage behind an electrostatic precipitator that is already installed, including a third-party one, so the odor problem is addressed without replacing the equipment that already handles the smoke. Stages connect on standard flange dimensions with transition pieces supplied to match your duct. The two things to check first are whether the plant room has the length for the extra modules, or whether they need stacking, and whether the existing fan has the static pressure margin for the added resistance.
Get a Quote

Get an Ecology Unit Configured for Your Project

Send the extract rate, the cooking style and the plant room dimensions. You get a stage-by-stage configuration and a quotation back.

Request a Quote for a Kitchen Ecology Unit

We reply during support hours, Mon–Fri 8:00–17:00 (GMT+8), with a stage-by-stage configuration and factory-direct pricing.

Prefer to send the extract rate over chat? Message us on WhatsApp →

Reply Mon–Fri (GMT+8)NDA AvailableFactory DirectFree System Design

1-year warranty on the complete unit • MOQ 1 unit • Lead time 7–15 days • UV lamps and carbon media are consumables

📱 WhatsApp

+86 159 5010 9153

🏭 Manufacturer

Jiangsu Polygee Environmental Technology Co., Ltd.

BSE: 920802 • 225 Patents • Exported to 50 Countries

📜 Certifications

CE FQC2602501 (LK, LK-E1 and UV series, to 2031) • ISO 9001 ABZB25Q30072R3M • ISO 14001 ABZB25E30043R3M • ISO 45001 ABZB25S30027R2M

Scope by product line is set out on the ESP certifications page.