An electrostatic precipitator datasheet is the maker’s own declaration for a model: its rated airflow, dimensions, connections, supply and design ratings. It measures nothing and certifies nothing. The fifteen fields below let you mark each line on a supplier’s sheet as a declaration, a measurement or a blank, before the model goes into a tender or a purchase order.
The expensive reading error is not missing a field. It is reading one kind of line as another: a design percentage as a test result, a brochure supply voltage as the supply the unit will be built for, a series table as the dimensions of the model quoted, a row of certification logos as certificates. Each of those is a line on a datasheet that looks complete and is not, and each one surfaces later, in a tender query, on the drawing, or on delivery day.
This page helps you decide whether the datasheet that arrived with a kitchen ESP or ecology unit quotation can stand as the technical basis of that quotation, which of its lines need a basis attached before they mean anything, and what to send back when a line is blank. It gives a fifteen-field reading sheet, explains the three lines that carry a number without a meaning until their basis is stated, and fills the sheet in for our own datasheets, including the lines we leave blank on purpose. It does not select a model, price one or say whether a market accepts a given document. For the laboratory report behind an efficiency figure, see our electrostatic precipitator test report page; for the model tables themselves, see the LK-E series page.
| Question | Our answer |
|---|---|
| What a datasheet is | The maker’s declaration for a model: rated airflow, design efficiency tier, equipment resistance, supply, power, dimensions, flange, weight, collector cells, module interfaces |
| What it is not | A test report (a laboratory’s measurement of one unit under a named method) or a certificate (a body’s statement naming models); both are separate documents |
| The three lines that need a basis | Rated airflow (per unit or per duct), the efficiency figure (design tier, or tested at a stated airflow under a named method) and the pressure drop (collector field alone, or the complete unit, at which airflow) |
| The sheet | The 15-Field ESP Datasheet Reading Sheet: each field with what it tells you, what it cannot prove and what to ask for when it is blank or has no basis |
| Our own datasheets | Issued per series (LK, LK-E, HME, UV, CB) on request, emailed within one business day; the lines each one answers, and the lines left blank, are listed below |
| Lines we leave blank | Cleaning interval (stated in writing at quotation for the kitchen described), UV lamp life, ozone output, noise, fan data |
| Not on this page | Model selection, prices, the reading of a test report, the writing of a specification clause, drawing approval and the comparison of offers; each has its own page |
- What an ESP datasheet is, and what it is not
- The 15-Field ESP Datasheet Reading Sheet
- Rated airflow, efficiency and pressure drop: the three lines that need a basis
- Dimensions, flange, weight, supply and power: the lines that decide whether it fits and runs
- Our own datasheets, against the sheet
- Scope and limits
- Buyer record and key takeaways
- Frequently asked questions
What an ESP datasheet is, and what it is not
A kitchen ESP datasheet is written by the maker, about a model, and it declares what that model is built to: the airflow it is rated for, the design tier of its efficiency, the resistance of its collector field, the supply it is configured for, its envelope, its flange and its weight. Nobody outside the maker checks it. That is not a defect; a datasheet is the only document that can carry dimensions and connections, because only the maker knows them. The error is reading it as if someone had.
Two other documents travel with a quotation, and each one does a job the datasheet cannot. A test report is a laboratory’s record of one unit, tested at stated airflows and stated inlet loads, under a named method; its number is a measurement, and it holds for the model it names. A certificate is a certification body’s statement that named models were assessed against a named standard; it proves nothing about performance in your duct, and it covers only the models on its list. The three documents are written by three authors, and the first thing to settle on any quotation is which document is answering which line. Our ecology unit specification page sets the same three beside the consultant’s specification clause, from the writer’s side; this page reads them from the buyer’s side.
| Document | Who writes it | What its numbers are | What it cannot do | What to ask for |
|---|---|---|---|---|
| Datasheet | The maker | Declarations: rated airflow, design efficiency tier, equipment resistance, supply, power, dimensions, flange, weight, cells, interfaces | Prove a performance figure; stand in for a certificate | The sheet for the model quoted, not for the series |
| Test report | A laboratory | Measurements of one unit, at stated airflows, under a named method | Cover a model it does not name; predict the outlet in your kitchen | The full copy naming the model, the airflow and the method; read it on the test report page |
| Certificate | A certification body | A list of models assessed against a named standard, with a number and an expiry | Prove efficiency; cover a model outside its list | The copy whose list names the model quoted |
Our own datasheets are issued per series on request and emailed within one business day, as listed on the document request page. The LK sheet carries model-by-model dimensions, airflow, power supply, pressure drop and duct connection sizes. The LK-E, HME, UV and activated carbon sheets carry the fields their own models publish, which differ by module; the section on our own datasheets below lists them. A quotation from us arrives with the datasheet for the quoted models and the certificate copies that name them, as set out on our supplier profile. The sheet in the next section reads any supplier’s datasheet, ours included.
The 15-Field ESP Datasheet Reading Sheet
An electrostatic precipitator datasheet is read one field at a time, and every field gets one of three marks: a declaration the maker stands behind, a measurement with its basis attached, or a blank. The sheet below has one row per field. The second column says what the field tells you; the third says what it cannot prove, which is where most reading errors are made; the fourth says what to ask for when the field is blank or carries a number without its basis. Copy the first column into a spreadsheet, one column per model quoted, and fill it from the datasheet itself, not from the covering email.
A datasheet that fills all fifteen fields for the model quoted, with the three basis lines stated, can stand as the technical basis of the quotation. A sheet with blanks is completed by questions before the model goes into a tender or an order; a blank is not a mark against the supplier, but a filled line that contradicts the quotation is.
The 15-Field ESP Datasheet Reading Sheet (our own reading sheet, not an industry standard)
| # | Field | What it tells you | What it does not prove | If blank, or no basis: ask for |
|---|---|---|---|---|
| 1 | Model number and series | Which exact model the lines below belong to; the series name alone covers several cabinets | That this model is the one on the quotation; a series brochure is not a model sheet | The page for the quoted model, with the model number printed on it |
| 2 | Rated airflow, and its basis | The nameplate airflow of one unit, in m³/h or CFM, and therefore how many units the design airflow needs | That the unit treats the airflow your fan actually delivers; that one unit covers one duct | The model selected at the design airflow, and the number of units in parallel, stated on the quotation |
| 3 | Efficiency figure, and its basis | Either a design tier (a declaration) or a tested value with its airflow, method, model, report number and laboratory | The outlet in service; a percentage without an airflow or a method is a tier, not a result | The report naming the model and the airflow; the fourteen fields to read are on our test report page |
| 4 | Pressure drop, and its basis | The resistance the unit adds, either for the collector field alone or for the complete unit with its distribution plate, at a stated airflow | The static pressure your fan has left; two figures on different bases are not compared | The complete-unit figure at the design airflow, in writing |
| 5 | Supply voltage, frequency and phase | The supply the printed model is built for; on a configured-to-order unit it is the brochure default | That it matches the panel on your site | The site supply, read at the panel, written on the proforma invoice (row 7 of our enquiry sheet) |
| 6 | Power consumption | The rated input of the unit at the stated supply, in watts; the high-voltage power supply is the main load | Running cost, which depends on hours; the fan’s power, which is not a property of the module | Watts per unit at the stated supply, fan excluded |
| 7 | Dimensions L × W × H | The cabinet envelope of one module | The installed length: connections between modules and transition pieces sit outside the envelope | The general arrangement drawing for the configuration; see our drawing approval page |
| 8 | Flange size A × B | The duct connection at inlet and outlet | That it bolts to your duct; two flanges of one size can carry different hole patterns | The hole pattern (field 9) |
| 9 | Bolt-hole pattern | Pitch, hole diameter and edge distance of the flange holes; usually on the drawing rather than the datasheet | Nothing more; where the pattern differs from the duct, an adapter plate is routine and adds length | The flange detail on the drawing for the model |
| 10 | Weight | The mass of one module, for hangers, slab and lifting | The train total: three modules are three point loads, not one average | Weight per module, where the datasheet leaves it blank |
| 11 | Collector cells | Material of the plates, whether the cells are washed and reused, and how they are withdrawn | The cleaning interval, which is not a datasheet line on any honest sheet; it depends on the cooking duty and hours | Cell material and withdrawal side; the cleaning regime, stated in writing at quotation for your kitchen |
| 12 | Module interfaces | Whether UV and activated carbon modules share the flange family, so a train can be built on one duct run | That stages can go in any order; the electrostatic stage stays ahead of the gas-phase stages | Module flange sizes and the stage order the maker builds to |
| 13 | Access and maintenance space | The clear distance needed in front of the access face to withdraw cells, lamps or carbon frames | That the space exists on your site; it is measured to the nearest obstruction, not to the wall | The figure per module, and the service side marked on the drawing |
| 14 | Ingress protection | An IP code, where a certificate names the models tested to it, for an outdoor or wet position | Weather protection by itself; an indoor model placed outdoors needs the record or an enclosure | The IP certificate naming the model, or a proposal for the enclosure |
| 15 | What is not on the sheet | Certificates, test reports, cleaning interval, fan data, noise, lamp life and ozone each belong to another document, or to a blank the maker chose to leave | That a line missing here is a line the supplier cannot answer | Each from its own document; or accept the blank and record why |
Decision rule. IF fields 2, 3 and 4 carry numbers with no basis beside them, THEN return the sheet with those three lines queried before anything else is read, BECAUSE the physical fields below them are only worth checking for a model that is the right size, at the claimed efficiency and within the fan’s allowance. The three basis lines are the subject of the next section; the physical lines follow.
Rated airflow, efficiency and pressure drop: the three lines that need a basis
Three lines on every datasheet carry a number that means nothing until its basis is stated: the airflow it is rated at, the efficiency figure and the pressure drop. The other twelve fields are either plain facts about a box or references to another document. These three move with airflow, with method and with where the measurement was taken, and a figure printed without those conditions is a declaration however many decimals it carries.
Rated airflow is the nameplate figure the maker assigns to the model, and the two questions to put to it are whether it is per unit or per duct, and what airflow the other two lines were read at. The Chinese test regulation that our laboratory reports cite, HJ/T 62-2001, in force since 2001-08-01, tests a unit at its rated airflow and again at 80% and 120% of it, with the inlet concentration adjusted. That is the clearest statement a method can make that the rating is a reference point and not a promise: the same unit is expected to read differently above and below it. A datasheet that prints one airflow and one efficiency is quoting the reference point only.
The efficiency figure is either a design tier or a measurement, and the datasheet should say which. Our LK-E range is published in three design tiers, 90%, 95% and at least 98% for the E0, E1 and E2 grades, marked as design efficiency on the LK-E series page; a tier is what the grade is built to, not a laboratory result for the model you are quoted. A measurement is a different thing, and it comes with its conditions. One of our LK120 units, tested by one laboratory under HJ/T 62-2001, read 97.4% at 80% of rated airflow, 96.0% at rated airflow and 95.2% at 120% of it, in the report numbered 2024I20-35-5322488001. The three figures are one model on one day. Which of them applies to your duct depends on the airflow your fan delivers. The highest figure in our LK range, up to 97.6%, was read on an LK160 at 16,000 m³/h in report ZY05W230298, and that is how it is quoted: with its model, its airflow and its report. A datasheet percentage with none of those is a tier, and goes into a tender as a tier.
Two other methods are named on specifications and should be recognized on sight. ASTM F2519-05(2025), the Standard Test Method for Grease Particle Capture Efficiency of Commercial Kitchen Filters and Extractors, is active and was last updated on 2025-08-22; its clause 1.1 says it can be used to determine the grease particle capture efficiency of components and systems. A figure quoted under it is a measurement under that method, not under HJ/T 62-2001, and the two are not compared number for number; our ASTM F2519 page explains why. UL 867, Electrostatic Air Cleaners, is an electrical safety standard; a listing under it says nothing about grease efficiency, and a datasheet that puts a UL mark beside an efficiency figure is placing two unrelated statements on one line. Our listing under File E522667 covers the LK and SE 6K, 12K and 18K models at 230 V, 50 Hz.
Pressure drop has two bases, and datasheets from different makers use different ones without saying so. The first is the collector field alone: the resistance of the cells and their frames. The second is the complete unit, with the air-distribution plate that spreads the flow across the field, at a stated airflow. Our LK-E sheet prints an equipment resistance of 23, 31 and 34 Pa for the E1, E0 and E2 grades, which is the field itself; our in-duct units are quoted as a complete unit, with the standard air-distribution plate, at no more than 150 Pa. The two figures are not in conflict; they are two bases, and the one the fan selection needs is the complete-unit figure at the design airflow. How two quotations can print the same stage with figures that are not comparable is worked through on our ecology unit price page. An integrated ESP hood with its own fan is not quoted with a pressure drop figure, which is why our HME sheet has no such line.
| Line | Read as a declaration when | Read as a measurement when | What the fan selection or the tender actually needs |
|---|---|---|---|
| Rated airflow | Printed alone, per model | Never; it is the reference point the other two lines are read at | The design airflow per duct, the model selected for it, and the number of units |
| Efficiency | A tier, or a percentage with no airflow, method or report | A figure with its airflow, method, model, report number and laboratory | The tier for the schedule row, marked design; the report for the clause that asks for evidence |
| Pressure drop | A figure with no basis and no airflow | A figure stated as field-only or complete-unit, at a named airflow, and where measured, with its report | The complete-unit figure at the design airflow, passed to whoever selects the fan |
Dimensions, flange, weight, supply and power: the lines that decide whether it fits and runs
The lines that stop an installation are the physical ones, and they have to be read for the model quoted, not for the series. A series table lists every cabinet in the range; the model on your quotation occupies one row of it, and the neighboring rows are the wrong dimensions for your duct. The first check on fields 7 to 10 is therefore that the row you are reading carries the model number on the quotation.
The second check is that the same airflow does not mean the same cabinet. On our LK-E sheet, two of the grades rated at 8,000 m³/h, the E1 and the E2, are different boxes. The LK80E1 is 1,524 × 560 × 833 mm with a 1,277 × 614 mm flange and weighs 116 kg. The LK80E2, at the same airflow, is 1,524 × 848 × 833 mm with the same flange and weighs 189 kg, and the sheet prints its rated power at 308 W. A quotation that upgrades the grade without re-issuing the row has changed the width and the weight of what arrives. Read the row for the grade quoted.
| Model (same rated airflow) | Rated airflow | Design tier | Dimensions L × W × H (mm) | Flange A × B (mm) | Weight (kg) | Rated power (W) |
|---|---|---|---|---|---|---|
| LK80E1 | 8,000 m³/h | 95%, design | 1,524 × 560 × 833 | 1,277 × 614 | 116 | Not printed on the E1 sheet |
| LK80E2 | 8,000 m³/h | At least 98%, design | 1,524 × 848 × 833 | 1,277 × 614 | 189 | 308 |
Two published rows from the LK-E datasheet; the full tables by grade are on the LK-E series page.
Flange and hole pattern. Field 8 says the connection size; it does not say the holes line up. Two flanges of one overall size can carry different pitches, hole diameters and edge distances, and the pattern usually lives on the drawing rather than the datasheet. Where it differs from the duct, an adapter plate is routine, but it adds length, and length is what a replacement position rarely has spare; the four measurements that settle a replacement are on our ESP replacement page. On a new installation the duct is drawn around the flange, so the datasheet figure is enough until the drawing stage.
Weight. A three-stage train is three point loads, and the heavy one is the carbon stage. Our published 8,000 m³/h example, an LK80E1 at 116 kg followed by a UV80 at 55 kg and a CB80 at 215 kg, is worked through on the ecology unit installation page. The point for the datasheet reader is that the weight line is read per module and passed to whoever designs the hangers, not averaged.
Supply. The supply printed on a datasheet is the supply the brochure model is drawn for, and on a configured-to-order unit it is a default. Our units are configured to order for 220 V or 380 V at 50 or 60 Hz, and the LK-E sheet prints 220 V, 50 Hz as its brochure input. What the unit is actually built for is what is written on the proforma invoice, and that figure comes from the panel that will feed the unit, read by the electrician making the connection, not copied from the datasheet. A unit built for the wrong supply is rebuilt, not adjusted, which is why row 7 of our enquiry sheet asks for the panel reading before a quotation is issued.
Power. The watts line is the rated input of the unit at the stated supply, and the high-voltage power supply is the main load; our LK-E2 sheet prints it per model, from 112 W on the LK30E2 upward, while the E0 and E1 sheets leave it blank. The fan is not in that figure on our sheets, and should not be assumed to be in anyone else’s, because the fan is selected against the total static pressure of the configuration and is not a property of the module.
Access and the outdoor position. Field 13 is the clear distance in front of the access face. Our UV and activated carbon modules publish a maintenance space of 1,000 mm; for an in-duct ESP the figure is model-specific and is confirmed with the configuration proposal, which is why field 13 asks for it on the drawing rather than from a catalog number. Field 14 only matters when the position is outdoors or wet, and then it matters a great deal. The IP code is defined in IEC 60529, Degrees of protection provided by enclosures, in its consolidated edition of 1989 with the amendments of 1999 and 2013. Our record is certificate BKC-190300574C of 2019, to EN 60529, the European adoption of that standard, naming LK30 to LK320 and LK30E1 to LK150E1 as tested to IP55. A model outside that list, or any other maker’s indoor model, placed on a roof needs either its own record or an enclosure in the quotation.
Decision rule. IF the datasheet row for the quoted model fills fields 7, 8 and 10, and the site has been measured for the service side and the straight run, THEN the next document is the general arrangement drawing, BECAUSE the datasheet gives the envelope of a module and only the drawing gives the installed length of the configuration. Transitions, hole pattern and service side appear on the drawing, not on the datasheet. What to check on that drawing before production starts is the subject of our drawing approval page.
Our own datasheets, against the sheet
Our datasheets are issued per series on request and read against the same fifteen fields as anyone else’s, so here is where each field is answered on ours, and which fields are answered by another document or left blank. Five sheets exist: the LK in-duct series, the LK-E engineering series in its three grades, the HME integrated ESP hood, the UV photolysis module and the CB activated carbon module. Each is emailed within one business day of a request through the document request page, and the sheet for the quoted models travels with every quotation.
| Field | Where it is answered on our documents |
|---|---|
| 1, 2, 7, 8, 10 | The series datasheet: model number, rated airflow, dimensions and flange size per model on the LK, LK-E, HME, UV and CB sheets; weight per model on the LK-E, UV and CB sheets, and on the product page tables for the LK range; the HME sheet leaves weight blank |
| 3 | Design tiers for the LK-E range, 90%, 95% and at least 98% for E0, E1 and E2, marked design. Measured figures are in third-party reports that name the model and the airflow, sent on request: up to 97.6% for the LK range on an LK160 at 16,000 m³/h (CMA-accredited laboratory, report ZY05W230298); 98.0% (report ZY01W220017) and 98.1% (report ZY07W250333) for the HME hood |
| 4 | The LK-E sheet prints the equipment resistance of the collector field (23, 31 and 34 Pa for E1, E0 and E2); the complete in-duct unit with its standard air-distribution plate is quoted at no more than 150 Pa; the HME hood, with its own fan, carries no pressure drop line; the UV and CB modules are stated at the design airflow on the quotation |
| 5 | The sheet prints the brochure input, 220 V, 50 Hz on the LK-E and UV sheets and 380 V, 50 Hz on the HME sheet; the carbon module has no supply line; every unit is configured to order for 220 V or 380 V at 50 or 60 Hz, and the supply built is the one written on the proforma invoice from your panel reading |
| 6 | Rated power per model on the LK-E2, HME and UV sheets; blank on the E0 and E1 sheets, so ask for it with the quotation |
| 9 | The flange detail on the drawing for the model, issued on request with the quotation |
| 11 | Stainless steel collector cells, drawer-style, withdrawn for washing and reused; the sheet does not print a cleaning interval; the interval for your kitchen is stated in writing with the quotation |
| 12 | Standard flanges across the LK-E, UV and CB modules, so the three stages join on one duct run, stacked or in line; the stage order we build to is electrostatic, then UV, then carbon |
| 13 | Maintenance space D = 1,000 mm on the UV and CB sheets; for the in-duct ESP, model-specific and confirmed with the configuration proposal; ask for it on the drawing |
| 14 | Certificate BKC-190300574C (2019, EN 60529): IP55 for LK30 to LK320 and LK30E1 to LK150E1; no IP line on the datasheet itself |
| 15 | Certificates by their own copies, each naming models: CE FQC2602501 (LK30 to LK480, LK30E1 to LK150E1, the UV series), RoHS 2.0 BKC25114877LC (for the lines it names, including LK, LK-E, SE and HME), the UL listing under File E522667 (LK and SE 6K, 12K and 18K at 230 V, 50 Hz; the standard is linked in the section above). The copies are on the certificates page and travel with the quotation |
Five lines are blank on our sheets, and blank on purpose. The cleaning interval depends on the cooking duty, the hours and the grease load, so we state it in writing at quotation for the kitchen described, not as a number on a page; a sheet that gives one interval for every kitchen is giving a sales figure. UV lamp life and ozone output are not printed because we hold no source we would put a number to. Noise is not a datasheet line; where a laboratory measured it on a unit, the figure is in that report and belongs to that unit. Fan data is not on any module sheet, because a fan can be supplied with a kitchen ecology unit and is then selected against the total static pressure of the configuration, which is a quotation line, not a catalog line. A reader who finds those five blanks on our sheet has found them where we put them.
Scope and limits
The sheet reads a document. Three things follow it, and reading the document well does not do them.
- Selection. The datasheet tells you what a model is; it does not tell you which model your kitchen needs. That follows from the cooking duty, the design airflow and the stages the discharge requires, as set out on our kitchen exhaust filtration page, and it is settled before the datasheet is read.
- The site. Fields 7 to 10 and 13 are interfaces with a duct, a panel and a plant room that the datasheet has never seen. A sheet can be complete and the unit can still not reach the position; that is settled on the drawing.
- Operation. Source capture at the hood, the airflow the fan actually delivers, the condition of the cells and the cleaning regime decide the outlet in service, and no field on a datasheet measures them. The regime is written into the order, as described on our cleaning page.
What this page does not do: it does not compare one maker’s datasheet with another’s as a product judgment, and it does not say whether a given market accepts a given document. It does not read a certificate of origin, a test report or a specification clause; each of those has its own page. Where a specification names a method or a document list, the documents we hold for the quoted models are assembled to that list, and the list is stated on row 9 of the enquiry sheet.
Buyer record and key takeaways
Before the model goes into a tender or a purchase order, your file should hold:
- The datasheet row for the model number on the quotation, with that number printed on the page you filed.
- The three basis lines resolved: the design airflow and the unit count; the efficiency marked as a tier or attached to a report; the complete-unit pressure drop at the design airflow, passed to whoever selects the fan.
- The supply the unit will be built for, from the panel reading, written on the proforma invoice rather than copied from the sheet.
- The weight per module and the access figure per module, passed to the hanger design and the drawing check.
- The certificate copies read against the model number, and the blanks you accepted, with the reason recorded beside each one.
Key takeaways
- Three authors: the datasheet declares, the report measures, the certificate names models; no one document does another’s job.
- Three basis lines: rated airflow, efficiency and pressure drop carry a number that means nothing until its airflow, method and basis are stated beside it.
- The row, not the table: dimensions, flange and weight belong to the model quoted; the same airflow in another grade is a different cabinet.
- Supply is written, not printed: the datasheet voltage is a default; the proforma invoice carries the one the unit is built for.
- Blanks are information: a cleaning interval, a lamp life or a noise figure printed without a source is a weaker line than an honest blank.
Frequently asked questions
- What should an electrostatic precipitator datasheet contain?
- For each model: the model number, rated airflow, the efficiency figure marked as a design tier or attached to a test report, the pressure drop with its basis and airflow, the supply voltage, frequency and phase, the rated power, dimensions, flange size, weight, the collector cell material and withdrawal, the module interfaces for UV and carbon stages, and the maintenance space. The bolt-hole pattern usually sits on the drawing, the IP rating on a certificate, and the cleaning interval on the quotation for your kitchen.
- Is the efficiency on a datasheet a tested value?
- Only if the sheet says so and names the airflow, the method, the model, the report number and the laboratory. A percentage printed alone is a design tier, which is the maker’s declaration of what the grade is built to. Our LK-E range is published in three design tiers, 90%, 95% and at least 98%, marked as design efficiency; our measured figures are in third-party reports that name the model and the airflow, such as 97.6% on an LK160 at 16,000 m³/h in report ZY05W230298.
- Why do two datasheets give such different pressure drops for similar units?
- Because they use different bases. One prints the resistance of the collector field alone; the other prints the complete unit with its air-distribution plate, at a stated airflow. Our LK-E sheet prints the field resistance, 23 to 34 Pa by grade, and our complete in-duct units are quoted at no more than 150 Pa with the standard plate. Ask every supplier for the complete-unit figure at your design airflow before the fan is selected.
- Can I use the supply voltage printed on the datasheet for my order?
- No. The printed supply is the brochure default. Our units are configured to order for 220 V or 380 V at 50 or 60 Hz, and the supply the unit is built for is the one written on the proforma invoice, taken from a reading at the panel that will feed it. A unit built for the wrong supply is rebuilt rather than adjusted, so the reading is sent with the enquiry.
- Which lines does your datasheet leave blank, and why?
- Cleaning interval, UV lamp life, ozone output, noise and fan data. The cleaning interval is stated in writing at quotation for the kitchen described, because it depends on the cooking duty and hours. Lamp life and ozone output are not printed because we hold no source we would put a number to. Noise belongs to the laboratory report of the unit it was measured on. The fan is selected against the total static pressure of the configuration and appears on the quotation, not on a module sheet.
Holding a datasheet with blank fields?
Send us the model number on your quotation and the design airflow. We send the datasheet for that model, the certificate copies that name it, and on request the test report with its airflow and report number, within one business day; mark the fifteen fields from those documents and send back any you cannot fill. If the quotation is ours, the sheet is already in it; if it is another supplier’s, send the design airflow and we send the datasheet for the equivalent model in our range, so that both sheets can be read on one basis.
Send the model number and the airflow →
If the quotation has not been requested yet, start with the ten-input enquiry sheet; a quotation written against it arrives with the datasheet for the quoted models and the three basis lines already stated.
Why we write this. The datasheet is the one document on a quotation that nobody outside the maker checks, and it is read as though someone had. The questions behind it are whether the percentage on another maker’s sheet is a test result, and whether the voltage on ours is the one the unit will be built for. This page answers both by reading the sheet one field at a time. It does not select or price equipment; selection and quotation live on the product pages.
Law manages project delivery at Polygee and reviews the airflow, stage and interface lines of offers against the site before an order is confirmed. Polygee, founded in 2004, manufactures the in-duct electrostatic precipitators, kitchen ESP hoods and kitchen ecology units named here and has exported to 50 countries. This page states our published documents and a method for reading them; it is not a specification, a selection or an opinion on any other supplier’s product.
References & further reading
- Test regulation cited on our laboratory reports: HJ/T 62-2001, Test regulation for cooking fume control equipment (in force 2001-08-01; tests at rated airflow and at 80% and 120% of it). mee.gov.cn
- Capture-efficiency method named on North American specifications: ASTM F2519-05(2025), Standard Test Method for Grease Particle Capture Efficiency of Commercial Kitchen Filters and Extractors (active; updated 2025-08-22). store.astm.org
- Ingress protection: IEC 60529, Degrees of protection provided by enclosures (IP Code), consolidated edition 1989 with amendments 1 (1999) and 2 (2013). webstore.iec.ch
- Electrical safety: UL 867, Electrostatic Air Cleaners. shopulstandards.com
- Our own documents: the document request page (series datasheets, manuals, certificate pack and test reports, emailed within one business day), the LK-E series page (model tables by grade) and the certificates page (certificate copies by product line).
Related reading
- Electrostatic precipitator test report: the fourteen fields to read on the laboratory report behind any efficiency figure on field 3.
- Ecology unit specification: the thirty clauses a consultant writes, and which document answers each one, from the writer’s side.
- Electrostatic precipitator quotation comparison: the sixteen lines that put three offers on one basis once each datasheet has been read.
- Electrostatic precipitator quotation: the ten inputs to send so that the datasheet that comes back is for the right model at the right airflow.