Chat on WhatsApp

Get a Free Quote in 24 Hours

Tell us your kitchen airflow and requirements — our engineers will send a sized proposal within one working day.

Get Quote

Electrostatic Precipitator Supplier for Commercial Kitchens: Own Factory in Zhangjiagang, MOQ 1 Unit, 7–15 Day Lead Time

Polygee is the manufacturer, not a trading company. As an electrostatic precipitator supplier with its own factory at No. 8 Ansheng Road, Zhangjiagang, Jiangsu, Jiangsu Polygee Environmental Technology Co., Ltd. (BSE: 920802) has designed, built and shipped kitchen ESP units to 50 countries since 2004. Every unit is inspected before it leaves the plant.

📦 MOQ 1 unit · 7–15 day lead time on standard models · certificate copies sent with every quotation
Supplier Profile

Supplier Facts at a Glance

The items a purchasing department checks before it approves a new electrostatic precipitator supplier, in one place: who we are, where the factory is, and the commercial terms behind an order.

Polygee ESP factory campus aerial view Polygee ESP assembly production line Polygee quality testing facility Polygee factory exterior view

Jiangsu Polygee Environmental Technology Co., Ltd. (BSE: 920802) is a Beijing Stock Exchange-listed manufacturer of commercial kitchen exhaust purification equipment, founded in 2004. The listing means audited accounts and public filings, which is the first thing many procurement teams ask a Chinese supplier for.

Production runs in a 110,000㎡ self-owned manufacturing base in Zhangjiagang with MES-driven lines and an in-house testing area. Purification efficiency is documented by CMA-accredited third-party tests (LK series up to 97.6% at the tested airflow).

We hold 225 patents granted (39 invention patents) and publish our certificate numbers by model: CE (FQC2602501), UL 867 on three listed models (File E522667), RoHS by series and ISO 9001 / 14001 / 45001. The full scope of each document is in the table further down this page.

2004
Founded in
Zhangjiagang
225
Patents
Granted
110,000㎡
Self-Owned
Factory Area
50
Countries
Exported To
Legal nameJiangsu Polygee Environmental Technology Co., Ltd. (brand: Polygee)
Factory and registered addressNo. 8 Ansheng Road, Jinfeng Town, Zhangjiagang, Suzhou, Jiangsu 215625, China
Founded / listing2004 · Beijing Stock Exchange, stock code 920802 (listed 2023)
People and site300+ employees · 110,000㎡ self-owned manufacturing base
Patents225 patents granted, including 39 invention patents
MOQ1 unit. Project and volume pricing quoted per project
Lead time7–15 days for standard models; OEM and customized orders quoted individually
Payment30% deposit (50% on some orders), balance paid before shipment. T/T and L/C accepted
IncotermsArranged to suit the buyer (EXW / FOB / CIF); shipments leave from Shanghai Port
Warranty1 year on the complete unit, including the ESP cell and SPP power supply. UV lamps and activated carbon media are consumables and not covered; on-site labor is a paid service
Spare partsCommon spare parts kept in stock; supply continues for 1 year after a model is discontinued
Sales and technical hoursMon–Fri 8:00–17:00 (GMT+8); quotations within 24 hours on business days
ConfidentialityNDA signed by the company on request
What We Manufacture

Six Product Families, All Built In-House

In-duct electrostatic precipitators from 2,000 m³/h per unit, scalable in parallel, plus the hood, odor-control and combined units that go around them. Each card links to the product page with models and specifications.

Polygee LK-K Series top-tier in-duct electrostatic precipitator

In-Duct ESP: LK-K / LK-D / LK-A

Three tiers of plate-type in-duct units for retrofits and new ductwork. In-duct kitchen electrostatic precipitator models

Polygee LK-E1 Series E1-tier engineering electrostatic precipitator

Engineering ESP: LK-E0 / E1 / E2

Engineering-grade units with 90%, 95% and 98% design efficiency tiers for larger and stricter projects. LK-E series

Polygee integrated kitchen ESP hood

Integrated ESP Hood (HME)

Exhaust hood with factory-fitted ESP cells, LED lighting and oil drainage in one stainless steel unit. Kitchen ESP hood

Polygee UV-C photolysis odor control module for commercial kitchens

UV-C Odor Control Module

Dual-band UV-C stage installed downstream of the ESP for gaseous cooking odors. UV kitchen odor control

Polygee activated carbon adsorption filter for kitchen exhaust

Activated Carbon Filter

Coal-based columnar carbon adsorption stage for residual odor after the ESP and UV stages. Activated carbon filter

Polygee kitchen ecology unit with ESP, UV-C and activated carbon stages

Kitchen Ecology Unit

ESP, UV-C and carbon stages supplied as one train for sites with an odor requirement as well as a grease requirement. Kitchen ecology unit

📋 Every model has a datasheet; ask for the one matching your airflow
🔧 Washable stainless steel collector cells on all ESP units
🏭 Cells, SPP power supplies and cabinets made on site
Certification Scope

Which Document Covers Which Model

Certificates are issued per series or per model, never for a whole catalog. Match the model number on your order against the document, and ask for a copy before you sign. The complete list with validity dates is on the ESP certificates page. If you are writing the tender, the clause-by-clause version, with the document that answers each clause, is on our ecology unit specification page.

DocumentNumberModels or scope it coversHow to verify
UL 867 (Listed)File E522667LK / SE 6K, 12K and 18K models, 230V/50HzUL Product iQ
CE (MD + EMC + LVD)FQC2602501LK series (LK30–480), LK-E series, UV series; valid to 2031-01-09Copy on request
CE (LVD + EMC), UDEMM.2024.206.C109410LK series; valid to 2029-11-07Copy on request
CE (LVD + EMC), UDEMM.2024.206.C109411SPP high-voltage power supply; valid to 2029-11-07Copy on request
CE (LVD + EMC), UDEMM.2025.206.C132198HPS integrated hood unit; valid to 2030-12-22Copy on request
Tested to EN standards (ICR Verification of Conformity)VC/UA221104–07SE / UV / HME / FMC series; valid to 2027-11-06Copies on request
RoHS 2.0BKC25114877LCLK, SE, HME, FMC, HPS, LK-E seriesCopy on request
IP55 (EN 60529)BKC-190300574CLK30–LK320, LK30E1–LK150E1 (tested 2019)Report on request
ISO 9001:2015ABZB25Q30072R3MCompany quality management system; valid to 2029-08-23Copy on request
ISO 14001:2015ABZB25E30043R3MCompany environmental management system; valid to 2028-12-27Copy on request
ISO 45001:2018ABZB25S30027R2MCompany occupational health and safety; valid to 2028-09-17Copy on request
CCEP (China)CCAEPI-EP-2024-757 / -877 / -608 / -602LK / SE / FMC / HME seriesCopies on request
Third-party efficiency reports (CMA-accredited)ZY05W230298 · ZY05W230296 · 2024I20-35-532248800197.6% on LK160 and 97.0% on LK40 (Beijing Zhongyan Huanneng); 96.0% at rated airflow on LK120 (SQEP). Each figure applies at the tested airflow onlyReports on request

A listing or certificate proves what it names and nothing more: UL 867 addresses electrical safety and ozone limits, CE addresses conformity for the named series, and an efficiency report applies at the tested airflow. None of them replaces a site acceptance test. What to ask any ESP supplier for, and how to read each document, is set out in our commercial kitchen ESP buying guide.

Inside the Factory

A China Electrostatic Precipitator Factory You Can Audit

Cells, high-voltage power supplies and cabinets are made on site, with MES-managed production and an in-house testing area. The plant is about two hours from Shanghai; on-site tours and live video walkthroughs are both available.

🔎 Every unit inspected before shipment
🏭 MES-managed production lines
Where We Ship

Exported to 50 Countries, Shipped from Shanghai Port

A selection of the markets we have shipped Polygee units to. Incoterms are arranged to suit the buyer, and certificate copies travel with the shipping documents. Country pages set out the terms, the site supply and the port for the UAE, the UK, India, Saudi Arabia, Qatar, Singapore, Malaysia, Australia, Bahrain, Vietnam, Brazil, Turkey and Mexico.

🌍

Europe

UK, Germany, France, Italy, Spain, Netherlands, Poland, Sweden, Turkey, Finland, Greece, Portugal

🌍

Middle East & Africa

UAE, Saudi Arabia, Qatar, Kuwait, Oman, Bahrain, Egypt, Morocco, South Africa

🌏

Asia Pacific

Singapore, Malaysia, Thailand, Vietnam, Philippines, Indonesia, India, Pakistan, Bangladesh, Sri Lanka, Maldives, Hong Kong (China), Macao (China), Taiwan (China), South Korea, Japan, Australia

🌎

Americas

United States, Canada, Mexico, Colombia, Brazil

🚢

Logistics

FOB / CIF from Shanghai Port, or EXW at the factory gate; sea and air freight both arranged

📄

Import Documents

CE, RoHS and ISO copies for customs clearance, plus the UL listing for the three listed models

Reference Projects

Installations You Can Ask Us About

Year, series and unit count for each project. Contact details for a reference check are given on request, subject to the client agreeing.

Marina Bay Sands - Polygee ESP installed

Marina Bay Sands, Singapore

2012 · ODM units · 500 units

Tun Razak Exchange - Polygee ESP installed

Tun Razak Exchange, Kuala Lumpur

2022 · LK-E + UV series · 300 units

Dubai Mall - Polygee ESP installed

Dubai Mall, UAE

2017 · ODM units · 40 units

Waldorf Astoria Lusail Doha - Polygee ESP installed

Waldorf Astoria Lusail, Qatar

LK-E series · 30 units

DoubleTree by Hilton - Polygee ESP installed

DoubleTree by Hilton Weerawila, Sri Lanka

2017 · LK-E series · 10 units

University of Sydney - Polygee ESP installed

University of Sydney, Australia

2013 · RY series · unit count on request

How an Order Runs

Five Steps from Inquiry to Delivery

What you receive at each step, so there are no surprises between the first email and the container.

✉
Step 1
Inquiry
Send your cooking type, airflow or hood size, duct size, voltage and destination port
📄
Step 2
Quotation
Proforma invoice with Incoterms, datasheet and certificate copies within 24 hours on business days
📦
Step 3
Sample
MOQ 1 unit, so a single trial unit is a normal first order
🏭
Step 4
Production
7–15 days for standard models, with every unit inspected before packing
🚢
Step 5
Shipping and After-Sales
FOB / CIF from Shanghai Port; Mon–Fri 8:00–17:00 (GMT+8) technical support under a 1-year warranty
OEM / ODM and Distributors

Your Brand on Our Units, or Our Brand in Your Territory

Polygee has supplied ODM units to landmark projects since 2012 and runs a distributor program with territory terms. Both routes start with the same factory, the same inspection before shipment and the same 1-year warranty. OEM orders carry your logo and cabinet color on standard models; quantities and lead time are agreed case by case, and which certificates apply to an OEM-marked unit is confirmed in writing per order, model by model. ODM projects run through four steps: requirement discussion, design and prototyping, MES-managed production with inspection before packing, then delivery and after-sales support in your market. Distributors get territory terms, product training and marketing materials, and place a first trial order at the same MOQ of 1 unit.

  • OEM branding — your logo and cabinet color on standard models; quantities and lead time agreed case by case.
  • ODM development — the four-step program is described on the About Polygee page.
  • Distribution — territory terms, training and marketing materials for HVAC contractors and kitchen equipment dealers. Apply through the ESP distributor program.
  • Pricing — budget ranges and what a quotation includes are explained in our electrostatic precipitator price guide.
Polygee commercial kitchen electrostatic precipitator product family Hosting international distributors at HQ
Request a Quotation

Send Us the Inputs, Get a Quotation Within 24 Hours on Business Days

Cooking type, exhaust airflow or hood size, duct size, supply voltage and destination port are enough for a first quotation. You receive a proforma invoice with Incoterms, the datasheet and the certificate copies that apply to the quoted models. Where each input comes from, and what you receive against it, is on our ESP enquiry sheet page.

Polygee hosting international distributors at headquarters
🏛
BSE Listed Company (920802) Audited accounts and public filings
⚡
Reply Within 24 Hours on Business Days Mon–Fri 8:00–17:00 (GMT+8) · scarlett@polygee.com · WhatsApp +86 159-5010-9153
🔒
NDA Signed by the Company Drawings and project details stay confidential
FAQs

Questions Buyers Ask Before Approving a New Electrostatic Precipitator Supplier

Short answers to the supplier-vetting questions we hear most often. Product questions are answered on the ESP FAQ page.

A manufacturer. Jiangsu Polygee Environmental Technology Co., Ltd. builds its electrostatic precipitators at its own factory at No. 8 Ansheng Road, Jinfeng Town, Zhangjiagang, Jiangsu, China. The company is listed on the Beijing Stock Exchange (920802) and runs an ISO 9001:2015 quality system (ABZB25Q30072R3M). You are welcome to visit the plant before you order.

Yes. The MOQ is 1 unit. Standard models ship in 7–15 days, and a sample order is a normal step in our order process. Project and volume pricing is quoted per project.

UL 867 (File E522667) covers the LK / SE 6K, 12K and 18K models at 230V/50Hz. Other series are covered by CE, RoHS or CCEP as shown in the certification table on this page. Check the listing on UL Product iQ and match the model number on your order against the file, not against the brand.

Yes. The plant is about two hours from Shanghai. Book an on-site tour or a live video walkthrough of the production lines and the testing area through the form on this page.

Coverage differs by country. Where a local partner is in place we will connect you; where there is none, sales and technical support are handled directly from Zhangjiagang. Companies interested in representing Polygee can apply through the distributor program.

A proforma invoice with Incoterms and lead time, the datasheet for the quoted models, and copies of the certificates that apply to those models. Third-party test reports are sent on request.

Cooking type and number of cooking positions, exhaust airflow or hood dimensions, duct size at the installation point, supply voltage and frequency, and the destination port. If some of this is not known yet, send what you have and we will list the open points in the quotation.